The Effect of Load Fluctuations on the Effluent Concentration Produced by Fixed-Film Reactors
- 1 February 1985
- journal article
- Published by IWA Publishing in Water Science & Technology
- Vol. 17 (2-3) , 45-52
- https://doi.org/10.2166/wst.1985.0118
Abstract
Although time-varying loads to biological treatment processes are common, typical kinetic models are based on steady-state loads and conditions. This paper uses nonsteady-state kinetics to demonstrate the impact of load variations on the effluent concentration and load from fixed-bed biofilm reactors. The different responses for reactors having average loads that are high, intermediate, and low are compared. In most cases, time-varying input loading, in comparison with steady input loading, causes an increase in average effluent concentration; however, certain combinations of load variation and reactor type allow better performance than do steady-state loads.Keywords
This publication has 0 references indexed in Scilit: