Abstract
Cyclic voltammetry, hydrodynamic voltammetry (HDV) and amperometry were used to investigate the behaviour of uric acid at carbon(graphite)–epoxy resin electrodes modified with the following electrocatalysts: ferrocenes, phthalocyanines, phenoxazines, phenazines and hexacyanoferrate species. As no direct electrocatalytic oxidation of uric acid was apparent, enzyme-coupled mediation was studied using uricase with electrodes modified with ferrocene, cobalt phthalocyanine (CoPC) and Meldola's Blue, in the presence and absence of oxygen. Again, no electrocatalysis was observed so we exploited the specificity of the enzyme uricase, which is known to produce hydrogen peroxide from uric acid. This product has been shown to undergo electrocatalysis at modified electrodes, and preferentially traverses certain membranes, so this rationale was adopted for the ensuing studies. Cyclic voltammetry and amperometry were used to study the electrochemical behaviour of H2O2 in 0.05 mol dm–3phosphate buffer (pH 9.3). Hydrogen peroxide was found to be electroactive at substantially lower potentials (n= 5). Further studies were performed with and without cellulose acetate (CA) membranes using amperometry in stirred solution. Epoxy resin electrodes were simply dropcoated with CA. The membrane functioned as an effective barrier against a range of potential interferences, but allowed the selective detection of enzymically generated H2O2 from urate. This methodology was then translated to screen-printed electrodes (SPEs). Cyclic voltammetry was first used to establish the precision of electrode manufacture; this was 4.9%(n= 5). The SPEs were then modified by placing each inside a tube, one end of which was covered with a solvent cast (CA) membrance. This electrode–polymer configuration furnished similar permselective properties as the drop-coated devices. The solvent cast membranes were treated with various concentrations of uricase; when the membrane was loaded with 0.48 U of enzyme a measurable H2O2 signal was obtained at the CoPC–SPE for a solution containing 0.18 mmol dm–3 uric acid.Keywords
This publication has 29 references indexed in Scilit:
- Chemically modified, carbon-based electrodes and their application as electrochemical sensors for the analysis of biologically important compounds. A reviewThe Analyst, 1992
- Comparative study of the voltammetric behaviour of guanine at carbon paste and glassy carbon electrodes and its determination in purine mixtures by differential-pulse voltammetryThe Analyst, 1992
- Oxidase/peroxidase bilayer-modified electrodes as sensors for lactate, pyruvate, cholesterol and uric acidAnalytica Chimica Acta, 1991
- Development of screen-printed carbon electrodes, chemically modified with cobalt phthalocyanine, for electrochemical sensor applicationsAnalytica Chimica Acta, 1990
- Cobalt phthalocyanine/cellulose acetate chemically modified electrodes for electrochemical detection in flowing streams. Multifunctional operation based upon the coupling of electrocatalysis and permselectivityAnalytical Chemistry, 1988
- Electrocatalytic and analytical response of cobalt phthalocyanine containing carbon paste electrodes toward sulfhydryl compoundsAnalytical Chemistry, 1985
- Preconcentration of uric acid at a carbon paste electrodeBioelectrochemistry and Bioenergetics, 1984
- Potential-dependent enzymic activity in an enzyme thin-layer cellAnalytical Chemistry, 1982
- Electrochemical Oxidation of Uric Acid and Xanthine at the Pyrolytic Graphite ElectrodeJournal of the Electrochemical Society, 1972
- Studies on uricaseBiochimica et Biophysica Acta, 1956