Monte Carlo simulations of dose near a nonradioactive gold seed
- 20 November 2006
- journal article
- Published by Wiley in Medical Physics
- Vol. 33 (12) , 4614-4621
- https://doi.org/10.1118/1.2388573
Abstract
The relative doses and hot/cold spot positions around a non-radioactive gold seed, irradiated by a 6 or 18 MV photon beam in water, were calculated using Monte Carlo simulation. Phase space files of 6 and 18 MV photon beams with a field size of 1 x 1 cm2 were generated by a Varian 21 EX linear accelerator using the EGSnrc and BEAMnrc code. The seed (1.2 x 1.2 x 3.2 mm3) was positioned at the isocenter in a water phantom (20 x 20 x 20 cm2) with source-to-axis distance = 100 cm. For the single beam geometry, the relative doses (normalized to the dose at 5 mm distance above the isocenter) at the upstream seed surface were calculated to be 1.64 and 1.56 for the 6 and 18 MV beams respectively when the central beam axis (CAX) is parallel to the width of the seed. These doses were slightly higher than those (1.58 and 1.52 for 6 and 18 MV beams respectively) calculated when the CAX is perpendicular to the width of the seed. Compared to the relative dose profiles with the same beam geometry without the seed in the water phantom, the presence of the seed affects the dose distribution at about 3 mm distance beyond both the upstream and downstream seed surface. For a pair of opposing beams with equal and unequal beam weight, the hot and cold spots of both opposing beams were mixed. For a 360 degree photon arc around the longitudinal axis of the seed, the relative dose profile along the width of the seed was similar to that of the opposing beam pair, except the former geometry has a larger dose gradient near the seed surface. In this study, selected results from our simulation were compared to previous measurements using film dosimetry.Keywords
This publication has 16 references indexed in Scilit:
- Internal fiducial markers can assist dose escalation in treatment of prostate cancer: result of organ motion simulationsPhysics in Medicine & Biology, 2005
- Optimization of collimator parameters to reduce rectal dose in intensity-modulated prostate treatment planningMedical Dosimetry, 2005
- Dose measurements near a non-radioactive gold seed using radiographic filmPhysics in Medicine & Biology, 2005
- Dosimetric consequences of the application of off-line setup error correction protocols and a hull-volume definition strategy for intensity modulated radiotherapy of prostate cancerRadiotherapy and Oncology, 2005
- Individualized planning target volumes for intrafraction motion during hypofractionated intensity-modulated radiotherapy boost for prostate cancerInternational Journal of Radiation Oncology*Biology*Physics, 2005
- Impact of geometric uncertainties on evaluation of treatment techniques for prostate cancerInternational Journal of Radiation Oncology*Biology*Physics, 2005
- On-line aSi portal imaging of implanted fiducial markers for the reduction of interfraction error during conformal radiotherapy of prostate carcinomaInternational Journal of Radiation Oncology*Biology*Physics, 2004
- Optimization of conformal radiation treatment of prostate cancer: Report of a dose escalation studyInternational Journal of Radiation Oncology*Biology*Physics, 1997
- Prostate motion during standard radiotherapy as assessed by fiducial markersRadiotherapy and Oncology, 1995
- BEAM: A Monte Carlo code to simulate radiotherapy treatment unitsMedical Physics, 1995