Improved Procedural Efficacy of Pulmonary Vein Isolation Using the Novel Second‐Generation Cryoballoon
Top Cited Papers
- 24 December 2012
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 24 (5) , 492-497
- https://doi.org/10.1111/jce.12082
Abstract
Introduction The cryoballoon technology has the potential to isolate a pulmonary vein (PV) with a single energy application. However, using the first-generation cryoballoon (CB-1G) repeated freezing or additional focal ablation is often necessary. The novel second-generation cryoballoon (CB-2G) features a widened zone of optimal cooling comprising the whole frontal hemisphere. The aim of this study was to investigate the impact of the novel design on procedural efficacy of cryoballoon PV isolation (CB-PVI). Methods and Results Single transseptal CB-PVI using an endoluminal spiral mapping catheter was performed in 60 consecutive patients (CB-1G, 28 mm, 300 seconds application time: 30 patients; CB-2G, 28 mm, 240 seconds application time: 30 patients). When compared to the CB-1G, using the CB-2G increased single-shot PVI rate from 51% to 84% (P < 0.001) and decreased procedure duration (128 ± 27 vs 98 ± 30 minutes; P < 0.001), and fluoroscopy exposure time (19.5 ± 7.4 vs 13.4 ± 5.3 min; P = 0.001). Effective CB-2G PVI could be performed with increased real-time PVI visualization rate (49% vs 76%; P < 0.001). Time to PVI (TPVI) was shorter in the CB-2G group (79 ± 60 vs. 52 ± 36 seconds; P = 0.049). Procedure-related complications occurred in 2 patients in the CB-1G group and 1 patient in the CB-2G group. Conclusions The CB-2G significantly improved procedural efficacy compared to the CB-1G and provided reliable TPVI measurement. TPVI may be used to adjust application time and number individually in future studies. Final conclusions regarding the safety profile of the CB-2G requires additional research.Keywords
This publication has 22 references indexed in Scilit:
- Intracardiac Echocardiography Improves Procedural Efficiency During Cryoballoon Ablation for Atrial Fibrillation: A Pilot StudyJournal of Cardiovascular Electrophysiology, 2010
- Pulmonary venous isolation by antral ablation with a large cryoballoon for treatment of paroxysmal and persistent atrial fibrillation: medium-term outcomes and non-randomised comparison with pulmonary venous isolation by radiofrequency ablationHeart, 2010
- Esophageal Endoscopy Results After Pulmonary Vein Isolation Using the Single Big Cryoballoon TechniqueJournal of Cardiovascular Electrophysiology, 2010
- The Permanency of Pulmonary Vein Isolation Using a Balloon Cryoablation CatheterJournal of Cardiovascular Electrophysiology, 2010
- Cryoballoon Pulmonary Vein Isolation with Real‐Time Recordings from the Pulmonary VeinsJournal of Cardiovascular Electrophysiology, 2009
- The esophageal effects of cryoenergy during cryoablation for atrial fibrillationHeart Rhythm, 2009
- The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre studyEuropean Heart Journal, 2008
- Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcomeEuropean Heart Journal, 2007
- Efficacy and Safety of Circumferential Pulmonary Vein Isolation Using a Novel Cryothermal Balloon Ablation SystemJournal of the American College of Cardiology, 2005
- How Close Are the Phrenic Nerves to Cardiac Structures? Implications for Cardiac InterventionalistsJournal of Cardiovascular Electrophysiology, 2005