Abstract
A theoretical framework is presented for understanding the effects of noise on estimates of the eigenvalues and eigenvectors of the diffusion tensor at moderate to high signal‐to‐noise ratios. Image noise produces a random perturbation of the diffusion tensor. Power series solutions to the eigenvalue equation are used to evaluate the effects of the perturbation to second order. It is shown that in anisotropic systems the expectation value of the largest eigenvalue is overestimated and the lowest eigenvalue is underestimated. Hence, diffusion anisotropy is overestimated in general. This result is independent of eigenvalue sorting bias. Furthermore, averaging eigenvalues over a region of interest produces greater bias than averaging tensors prior to diagonalization. Finally, eigenvector noise is shown to depend on the eigenvalue contrast and imposes a theoretical limit on the accuracy of simple fiber tracking schemes. The theoretical results are shown to agree with Monte Carlo simulations. Magn Reson Med 46:1174–1188, 2001.Keywords
This publication has 25 references indexed in Scilit:
- Diffusion tensor imaging can detect and quantify corticospinal tract degeneration after strokeJournal of Neurology, Neurosurgery & Psychiatry, 2000
- Minimal gradient encoding for robust estimation of diffusion anisotropy☆Magnetic Resonance Imaging, 2000
- Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imagingMagnetic Resonance in Medicine, 1999
- A Comparative Study of Acquisition Schemes for Diffusion Tensor Imaging Using MRIJournal of Magnetic Resonance, 1999
- Toward a quantitative assessment of diffusion anisotropyMagnetic Resonance in Medicine, 1996
- Water diffusion in the giant axon of the squid: Implications for diffusion‐weighted MRI of the nervous systemMagnetic Resonance in Medicine, 1994
- Determinants of anisotropic water diffusion in nervesMagnetic Resonance in Medicine, 1994
- A simple method for obtaining cross‐term‐free images for diffusion anisotropy studies in NMR microimagingMagnetic Resonance in Medicine, 1991
- Pulsed-gradient spin-echo diffusion studies in nmr imaging. Effects of the imaging gradients on the determination of diffusion coefficientsJournal of Magnetic Resonance (1969), 1990