Nonhydrostatic compression of elastically anisotropic polycrystals. I. Hydrostatic limits of 4:1 methanol-ethanol and paraffin oil
- 1 February 1998
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review B
- Vol. 57 (6) , 3253-3263
- https://doi.org/10.1103/physrevb.57.3253
Abstract
The compression of a foil of in 4:1 methanol-ethanol and paraffin oil pressure-transmitting media has been studied by energy-dispersive x-ray diffraction in a diamond-anvil cell. Line shifts and line profiles are used to analyze elastic and plastic strains. The increasing viscosity of 4:1 methanol-ethanol causes departures from hydrostatic conditions starting around 7 GPa even while the medium is in a liquid state. The glass transitions in the range 5–7 GPa for paraffin oil and 12–13 GPa for 4:1 methanol-ethanol cause a volume incompressibility and discontinuity followed by isotropic compression behavior. The hydrostatic limit of a liquid with respect to a polycrystalline sample may lie at pressures considerably below the pressure of solidification. For nonideal powders, even small departures from nonhydrostatic conditions of the pressure transmitting medium, often termed quasihydrostatic, can have a strong influence on the compression behavior.
Keywords
This publication has 32 references indexed in Scilit:
- Compression Behaviour of Elastically Anisotropic Polycrystals Using Energy-Dispersive X-ray DiffractionJournal of Synchrotron Radiation, 1997
- A facility for high-pressure X-ray diffraction at HASYLABNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997
- X-Ray and Neutron Diffraction in Nonideal CrystalsPublished by Springer Nature ,1996
- Deviatoric stress measurement under uniaxial compression by a powder x-ray diffraction methodJournal of Applied Physics, 1994
- The lattice strains in a specimen (cubic system) compressed nonhydrostatically in an opposed anvil deviceJournal of Applied Physics, 1993
- Specific volume measurements of Cu, Mo, Pd, and Ag and calibration of the ruby R1 fluorescence pressure gauge from 0.06 to 1 MbarJournal of Applied Physics, 1978
- Estimation of uniaxial stress component in NaCl samples compressed in a tungsten carbide anvil high-pressure x-ray apparatusJournal of Applied Physics, 1976
- Uniaxial stress component in tungsten carbide anvil high-pressure x-ray camerasJournal of Applied Physics, 1974
- Hydrostatic limits in liquids and solids to 100 kbarJournal of Applied Physics, 1973
- Pressure Measurement Made by the Utilization of Ruby Sharp-Line LuminescenceScience, 1972