Aneurysm Rupture Following Treatment with Flow-Diverting Stents: Computational Hemodynamics Analysis of Treatment
Top Cited Papers
Open Access
- 11 November 2010
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 32 (1) , 27-33
- https://doi.org/10.3174/ajnr.a2398
Abstract
BACKGROUND AND PURPOSE: Flow-diverting approaches to intracranial aneurysm treatment had many promising early results, but recent apparently successful treatments have been complicated by later aneurysm hemorrhage. We analyzed 7 cases of aneurysms treated with flow diversion to explore the possible rupture mechanisms. MATERIALS AND METHODS: CFD analysis of pre- and posttreatment conditions was performed on 3 giant aneurysms that ruptured after treatment and 4 successfully treated aneurysms. Pre- and posttreatment hemodynamics were compared including WSS, relative blood flows, vascular resistances, and pressures, to identify the effects of flow-diverter placements. RESULTS: Expected reductions in aneurysm velocity and WSS were obtained, indicating effective flow diversion from the sac into the parent artery, consistent with periprocedural observations. In each case with postaneurysm rupture, the result of flow diversion led to an increase in pressure within the aneurysm. This pressure increase is related to larger effective resistance in the parent artery from placement of the devices and, in 2 cases, the reduction of a preaneurysm stenosis. CONCLUSIONS: Flow-diversion devices can cause intra-aneurysmal pressure increases, which can potentially lead to rupture, especially for giant aneurysms. This relates both to changes in the parent artery configuration, such as reduction of a proximal stenosis, and to the flow diversion into higher resistance parent artery pathways combined with cerebral autoregulation, leading to higher pressure gradients. These may be important effects that should be considered when planning interventions. Potentially dangerous cases could be identified with angiography and/or patient-specific CFD models.This publication has 15 references indexed in Scilit:
- Treatment of Intracranial Aneurysms by Functional Reconstruction of the Parent Artery: The Budapest Experience with the Pipeline Embolization DeviceAmerican Journal of Neuroradiology, 2010
- CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICENeurosurgery, 2009
- Simulation of Stent Deployment in Patient-Specific Cerebral Aneurysm Models for Their Hemodynamics AnalysisPublished by ASME International ,2008
- Computational fluid dynamics of stented intracranial aneurysms using adaptive embedded unstructured gridsInternational Journal for Numerical Methods in Fluids, 2007
- A New Endoluminal, Flow-Disrupting Device for Treatment of Saccular AneurysmsStroke, 2007
- Intracranial aneurysm stenting: Follow‐up with MR angiographyJournal of Magnetic Resonance Imaging, 2006
- Endovascular treatment of intracranial aneurysms with parent vessel reconstruction using balloon and self expandable stentsActa Neurochirurgica, 2006
- Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: technique and sensitivityIEEE Transactions on Medical Imaging, 2005
- Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding techniqueIEEE Transactions on Medical Imaging, 2005
- Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysmsJournal of Neurosurgery, 2005