Plastic ELISA-on-a-Chip Based on Sequential Cross-Flow Chromatography
- 6 January 2006
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (3) , 793-800
- https://doi.org/10.1021/ac051453v
Abstract
A plastic chip that can perform immunoassays using an enzyme as signal generator, i.e., ELISA-on-a-chip, was developed by incorporating an immunostrip into channels etched on the surfaces of the chip. To utilize an analytical concept of cross-flow chromatography, the chip consisted of two cross-flow channels in the horizontal and vertical directions. In the vertical channel, we placed a 2-mm-wide immunostrip for cardiac troponin I (cTnI), which was identical to a conventional rapid test kit except for the utilization of an enzyme, horseradish peroxidase (HRP), as tracer. An enzyme substrate supply channel and a horizontal flow absorption pad compartment were transversely arranged on each lateral side of the signal generation pad of the strip, respectively. Upon application of a sample containing cTnI, it migrated vertically through the membrane strip by capillary action, and antigen−antibody binding occurred. After 15 min, the horizontal flow was initiated by the addition of a chromogenic substrate solution for HRP into the supply channel and by partial superimposition of the horizontal flow absorption pad onto the signal generation pad. A color signal proportional to the analyte concentration was produced on this pad, measured after 5 min as optical densities using a digital camera-based detector, and quantified by integration of the densities under the peak after normalization. Its calibration curve indicated that the detection limit of the chip was ∼0.1 ng/mL and its quantification limit was 0.25 ng/mL. In measuring blindly prepared samples, the chip performance correlated with that of a reference system, Beckman Coulter Access, within 2.5-fold discrepancy at the detection limit.Keywords
This publication has 19 references indexed in Scilit:
- A highly sensitive flow-through amperometric immunosensor based on the Peroxidase chip and enzyme-channeling principleBiosensors and Bioelectronics, 2003
- Characterisation of horseradish peroxidase immobilisation on an electrochemical biosensor by colorimetric and amperometric techniquesBiosensors and Bioelectronics, 2003
- Enzyme-linked immunosorbent assays in a chromatographic formatJournal of Chromatography A, 1996
- Luminometry: a novel bioluminescent immunoassay enhances the quantitation of mucosal and systemic antibody responsesJournal of Immunological Methods, 1996
- Multilabeling of Ferrocenes to a Glucose Oxidase-Digoxin Conjugate for the Development of a Homogeneous Electroenzymic ImmunoassayAnalytical Chemistry, 1994
- Bovine brucellosis: Evaluation of field sera by a competitive and superimposable ELISA utilising a monoclonal antibody against Brucella abortus lipopolysaccharideVeterinary Immunology and Immunopathology, 1989
- Clinical Evaluation of the Ortho Rubella ELISA Test SystemAmerican Journal of Clinical Pathology, 1984
- The adsorptive characteristics of proteins for polystyrene and their significance in solid-phase immunoassaysAnalytical Biochemistry, 1980
- Enzyme-linked immunosorbent assay (ELISA) quantitative assay of immunoglobulin GImmunochemistry, 1971
- Adapter for solvent evaporation on the top of the plate for prolonged developing time in thin-layer chromatographyAnalytical Chemistry, 1968