Continuous sample deposition from reversed-phase liquid chromatography to tracks on a matrix-assisted laser desorption/ionization precoated target for the analysis of protein digests
- 19 September 2002
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 23 (18) , 3193-3204
- https://doi.org/10.1002/1522-2683(200209)23:18<3193::aid-elps3193>3.0.co;2-y
Abstract
Peptide mass fingerprinting by matrix‐assisted laser desorption/ionization (MALDI)‐mass spectrometry (MS) is one of the standard high‐throughput methods for protein identification today. Traditionally this method has been based on spotting peptide mixtures onto MALDI targets. While this method works well for more abundant proteins, low‐abundance proteins mixed with high‐abundance proteins tend to go undetected due to ion suppression effects, instrumental dynamic range limitations and chemical noise interference. We present an alternative approach where liquid chromatography (LC) effluent is continuously collected as linear tracks on a MALDI target. In this manner the chromatographic separation is spatially preserved on the target, which enables generation of off‐line LC‐MS and LC‐MS/MS data by MALDI. LC‐MALDI sample collection provides improved sensitivity and dynamic range, spatial resolution of peptides along the sample track, and permits peptide mass mapping of low‐abundance proteins in mixtures containing high‐abundance proteins. In this work, standard and ribosomal protein digests are resolved and captured using LC‐MALDI sample collection and analyzed by MALDI‐TOF‐MS.Keywords
This publication has 41 references indexed in Scilit:
- GPC Separation of Polymer Samples for MALDI AnalysisAnalytical Chemistry, 2000
- MALDI induced saturation effects in chevron microchannel plate detectorsInternational Journal of Mass Spectrometry and Ion Processes, 1997
- Laser Vaporization/Ionization Interface for Capillary Electrophoresis−Time-of-Flight Mass SpectrometryAnalytical Chemistry, 1997
- Off-Line Coupling of Capillary Electrophoresis and Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass SpectrometryAnalytical Chemistry, 1995
- Continuous-Flow MALDI Mass Spectrometry Using an Ion Trap/Reflectron Time-of-Flight DetectorAnalytical Chemistry, 1995
- An approach to correlate tandem mass spectral data of peptides with amino acid sequences in a protein databaseJournal of the American Society for Mass Spectrometry, 1994
- Rapid identification of proteins by peptide-mass fingerprintingCurrent Biology, 1993
- Reversed-phase liquid chromatography/Fourier transform infrared spectrometry using concentric flow nebulizationAnalytical Chemistry, 1991
- Continuous recording of reflection-absorbance Fourier transform infrared spectra of the effluent of a microbore liquid chromatographAnalytical Chemistry, 1986
- Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4Nature, 1970