Palladium nitrate–magnesium nitrate modifier for electrothermal atomic absorption spectrometry. Part 4. Interference of sulfate in the determination of selenium
- 1 January 1992
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 7 (3) , 505-509
- https://doi.org/10.1039/ja9920700505
Abstract
The possible sources of sulfate interferences in the determination of selenium, even when stabilized temperature platform furnace conditions were used, were investigated using sulfuric acid, sodium sulfate and magnesium sulfate as model compounds. The molecular spectrum of CS was observed when sodium sulfate was volatilized. The most likely mechanism of interference in this instance is an expulsion of the analyte element with the violently volatilized matrix early in the atomization stage. Sulfuric acid and magnesium sulfate decompose at elevated temperatures with the formation of SO3, which was reduced at least in part to SO2 in the graphite tube. The most likely interference mechanism in these instances is the formation of SeO2 in the presence of excess of SO3 and its volatilization during the pyrolysis stage. Addition of barium nitrate to the palladium nitrate–magnesium nitrate modifier reduced the background absorption and also the sulfate interference significantly. In the presence of barium, sulfate is bound at least in part as barium sulfate, which decomposes in the atomization stage. This means that SeO2, if it is formed, is volatilized at temperatures which are high enough for its atomization. The proposed mixed modifier allows an interference-free determination of selenium in mineral waters with high sulfate content.Keywords
This publication has 18 references indexed in Scilit:
- Mechanisms of selenium vaporization with palladium modifiers using electrothermal atomization and mass spectrometric detectionAnalytical Chemistry, 1991
- Investigation and elimination of chloride interference on thallium in graphite furnace atomic absorption spectrometryAnalytical Chemistry, 1988
- Palladium nitrate-magnesium nitrate modifier for graphite furnace atomic absorption spectrometry. Part 2. Determination of arsenic, cadmium, copper, manganese, lead, antimony, selenium and thallium in waterJournal of Analytical Atomic Spectrometry, 1988
- Direct determination of selenium in solid biological materials by graphite furnace atomic absorption spectrometryJournal of Analytical Atomic Spectrometry, 1988
- Palladium nitrate-magnesium nitrate modifier for graphite furnace atomic absorption spectrometry. Part 1. Determination of arsenic, antimony, selenium and thallium in airborne particulate matterJournal of Analytical Atomic Spectrometry, 1988
- Direct experimental evidence for in situ graphite and palladium selenide formations with improvement on the sensitivity of selenium in graphite furnace atomic absorption spectrometryAnalytical Chemistry, 1987
- Spatially resolved absorbance profiles detailing the selenium vaporisation process in electrothermal atomisersJournal of Analytical Atomic Spectrometry, 1987
- Investigation of reactions involved in graphite furnace atomic absorption procedures: Part 12. A study of some factors influencing the determination of seleniumAnalytica Chimica Acta, 1986
- Palladium and magnesium nitrates, a more universal modifier for graphite furnace atomic absorption spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1986
- Determination of selenium in biological materials with platform furnace atomic-absorption spectroscopy and Zeeman background correctionThe Analyst, 1983