Noninvasive assessment of lung volume: Respiratory inductance plethysmography and electrical impedance tomography
- 1 March 2005
- journal article
- review article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 33 (3) , S163-S169
- https://doi.org/10.1097/01.ccm.0000155917.39056.97
Abstract
Respiratory inductance plethysmography (RIP) and electrical impedance tomography (EIT) are two monitoring techniques that have been used to assess lung volume noninvasively. RIP uses two elastic bands around the chest and abdomen to assess global changes in lung volume. In animal models, RIP has been shown to detect changes in lung mechanics during high-frequency oscillatory ventilation and has the potential to quantify lung volumes noninvasively. EIT measures regional impedance changes with 16 electrodes around the patient’s chest, each of them injecting and receiving small currents. Impedance changes have been correlated with volume changes in animal models and in humans. In a recent animal model, EIT was shown to be capable of tracking lung volume changes during high-frequency oscillatory ventilation. The promise of monitoring techniques such as RIP and EIT is that they will guide lung protective ventilation strategies and allow the clinician to optimize lung recruitment, maintain an open lung, and limit overdistension. EIT is the only bedside method that allows repeated, noninvasive measurements of regional lung volumes. In the future, it will be important to standardize the definitions of alveolar recruitment and ultimately demonstrate the superiority of EIT-guided ventilator management in providing lung protective ventilation.Keywords
This publication has 24 references indexed in Scilit:
- Prevention of Endotracheal Suctioning-induced Alveolar Derecruitment in Acute Lung InjuryAmerican Journal of Respiratory and Critical Care Medicine, 2003
- Comparison of loss in lung volume with open versus in-line catheter endotracheal suctioningPediatric Critical Care Medicine, 2003
- Optimal High-Frequency Oscillatory Ventilation Settings by Nonlinear Lung Mechanics AnalysisAmerican Journal of Respiratory and Critical Care Medicine, 2002
- Identification of optimal lung volume during high-frequency oscillatory ventilation using respiratory inductive plethysmographyCritical Care Medicine, 2001
- What Has Computed Tomography Taught Us about the Acute Respiratory Distress Syndrome?American Journal of Respiratory and Critical Care Medicine, 2001
- Lung Volume Recruitment in Lambs during High-Frequency Oscillatory Ventilation Using Respiratory Inductive PlethysmographyPediatric Research, 2001
- Detecting lung overdistention in newborns treated with high-frequency oscillatory ventilationJournal of Applied Physiology, 2000
- Real-time three-dimensional electrical impedance imagingPhysiological Measurement, 2000
- A new sensor for monitoring chest wall motion during high-frequency oscillatory ventilationMedical Engineering & Physics, 1999
- Adult respiratory distress syndrome profiles by computed tomographyJournal of Thoracic Imaging, 1986