Complications of neonatal extracorporeal membrane oxygenation
- 1 July 1994
- journal article
- research article
- Published by SAGE Publications in Perfusion
- Vol. 9 (4) , 241-256
- https://doi.org/10.1177/026765919400900402
Abstract
From 1973-1985 to 1988 the average patient complications per case were 1.44 per case and significantly increased during 1990 to 1992 to 2.10 per case (Figure 3). During the same periods patient survival significantly decreased from 84% (1973-1985 to 1988, n = 2463) to 80% (1990 to 1992, n = 4005) (Figure 4). The association between total complication rates and survival rate was examined by regression analysis (Table 5). The correlation of patient complication rate and total complication rate with survival is highly significant; however, causality cannot be established. When comparing different entry criteria (Table 2) for incidence of mechanical and patient complications, no significant differences are apparent. This is not surprising since each of the entry criteria were designed to identify the same patient population. When premature neonates (> 35 weeks) were placed on ECMO, 36% of them had intracranial haemorrhage (ICH) with 62% mortality while only 12% of the neonates < 35 weeks had ICH and a 49% mortality. Similar findings were noted with low birthweight neonates (< 2.2 kg), 28% had ICH with 64% mortality while only 12% of the neonates > 2.2 kg had ICH with a 50% mortality. Selection criteria remain problematic for a variety of reasons. They cannot be viewed as absolute because of variability between centres. What represents likely 80% mortality in one centre may not apply to another. Historical controls are misleading because changing respiratory therapy strategies make historical populations difficult to compare. Also, once an ECMO centre becomes established, a more challenging group of patients will be attracted than previously was the case. Further, a single entry criterion cannot be generalized for all entry diagnoses. Criteria for an 80% predicted mortality is probably not the same for MAS, CHN, PPHN, and sepsis. Subsequent patients registered in the Neonatal ECMO Registry of the Extracorporeal Life Support Organization will address these issues more thoroughly, as specific details of the pre-ECMO condition and therapeutic strategies are collected. This collective review should help to identify trends which require reassessment of technique or patient management.Keywords
This publication has 88 references indexed in Scilit:
- Malposition of extracorporeal membrane oxygenation cannulas in patients with congenital diaphragmatic herniaThe Journal of Pediatrics, 1993
- Mortality and morbidity rates among lower birth weight infants (2000 to 2500 grams) treated with extracorporeal membrane oxygenationThe Journal of Pediatrics, 1992
- Unsuspected congenital heart disease in neonates receiving extracorporeal life support: A review of ninety-five cases from the Extracorporeal Life Support Organization RegistryThe Journal of Pediatrics, 1992
- Timing of surgery in congenital diaphragmatic herniaAnaesthesia, 1991
- Changes in cardiac function during extracorporeal membrane oxygenation for persistent pulmonary hypertension in the newborn infantThe Journal of Pediatrics, 1991
- Hemolysis during long-term extracorporeal membrane oxygenationThe Journal of Pediatrics, 1989
- Imaging of cerebrovascular injury in infants treated with extracorporeal membrane oxygenationThe Journal of Pediatrics, 1989
- Right common carotid artery ligation in extracorporeal membrane oxygenationThe Journal of Pediatrics, 1988
- Ventilatory predictors of pulmonary hypoplasia in congenital diaphragmatic hernia, confirmed by morphologic assessmentThe Journal of Pediatrics, 1987