Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
Top Cited Papers
Open Access
- 10 July 2007
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 26 (2) , 375-385
- https://doi.org/10.1002/jmri.20969
Abstract
Purpose To evaluate the validity of different approaches to determine the signal-to-noise ratio (SNR) in MRI experiments with multi-element surface coils, parallel imaging, and different reconstruction filters. Materials and Methods Four different approaches of SNR calculation were compared in phantom measurements and in vivo based on: 1) the pixel-by-pixel standard deviation (SD) in multiple repeated acquisitions; 2) the signal statistics in a difference image; and 3) and 4) the statistics in two separate regions of a single image employing either the mean value or the SD of background noise. Different receiver coil systems (with one and eight channels), acquisitions with and without parallel imaging, and five different reconstruction filters were compared. Results Averaged over all phantom measurements, the deviations from the reference value provided by the multiple-acquisitions method are 2.7% (SD 1.6%) for the difference method, 37.7% (25.9%) for the evaluation of the mean value of background noise, and 34.0% (38.1%) for the evaluation of the SD of background noise. Conclusion The conventionally determined SNR based on separate signal and noise regions in a single image will in general not agree with the true SNR measured in images after the application of certain reconstruction filters, multichannel reconstruction, or parallel imaging. J. Magn. Reson. Imaging 2007.Keywords
This publication has 34 references indexed in Scilit:
- Image reconstruction in SNR units: A general method for SNR measurement†Magnetic Resonance in Medicine, 2005
- Parallel acquisition techniques for accelerated volumetric interpolated breath‐hold examination magnetic resonance imaging of the upper abdomen: Assessment of image quality and lesion conspicuityJournal of Magnetic Resonance Imaging, 2005
- Field‐of‐view limitations in parallel imagingMagnetic Resonance in Medicine, 2004
- High Spatial Resolution Whole-Body MR Angiography Featuring Parallel Imaging: Initial ExperienceRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- Scalable multichannel MRI data acquisition systemMagnetic Resonance in Medicine, 2003
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Signal-to-noise measures for magnetic resonance imagersMagnetic Resonance Imaging, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986