Effect of wall roughness on convective heat transfer in commercial pipes

Abstract
Heat transfer and friction measurements were made for air flow through a smooth copper pipe and six other commercial pipes, with a ratio of diameter to equivalent sand roughness varying from 640 to 64. The Reynolds number range was 10,000 to 80,000. Though some increase in heat transfer coefficients with roughness was found, the heat transmission per unit power loss always decreased.The momentum–heat‐transfer anlogies of Reynolds and Colburn are shown to be inadequate for handling the experimental data. Those of Prandtl and Taylor, von Kármán, and Pinkel fail to show a required Reynolds number dependence ofjhwhen friction factor has become independent of Reynolds number for a rough pipe. Martinelli's equation shows such dependence and, even in approximate form, gives good prediction of the experimental results.