Abstract
Proficiency assessments are important elements in quality control for diagnostic laboratories. Traditionally, proficiency testing for polymerase chain reaction (PCR)–based assays has involved the use of clinical samples, samples “spiked” with live agents or DNA plasmids. Because of government regulations and biosecurity concerns, distribution of live high-consequence pathogens of livestock and poultry, such as avian influenza, is not possible, and DNA plasmids are not technically suitable for evaluating RNA virus detection. Therefore, a proficiency testing panel using whole avian influenza in a diluent containing a phenolic disinfectant that inactivates the virus while preserving the RNA for at least 8 weeks at −70 C was developed and used in a multicenter proficiency assessment for a type A influenza real-time reverse transcriptase (RT)–PCR test. The test, which was highly standardized, except for variation in the real-time RT-PCR equipment used, was shown to be highly reproducible by proficiency testing in 12 laboratories in the United States, Canada, and Hong Kong. Variation in cycle threshold values among 35 data sets and 490 samples was minimal (CV = 5.19%), and sample identifications were highly accurate (96.7% correct identifications) regardless of real-time PCR instrumentation.Keywords
This publication has 17 references indexed in Scilit:
- Low-Pathogenicity H7N2 Avian Influenza Outbreak in Virginia During 2002Avian Diseases, 2003
- The Effect of Various Disinfectants on Detection of Avian Influenza Virus by Real Time RT-PCRAvian Diseases, 2003
- Achieving Quality Reproducible Results and Maintaining Compliance in Molecular Diagnostic Testing of Human PapillomavirusArchives of Pathology & Laboratory Medicine, 2003
- International Proficiency Study of a Consensus L1 PCR Assay for the Detection and Typing of Human Papillomavirus DNA: Evaluation of Accuracy and Intralaboratory and Interlaboratory AgreementJournal of Clinical Microbiology, 2003
- Quality control in nucleic acid testing—where do we stand?Journal of Clinical Virology, 2002
- Sensitivity and reproducibility of HCV quantitation in chimpanzee sera using TaqMan real-time PCR assayJournal of Virological Methods, 2002
- Development of a Real-Time Reverse Transcriptase PCR Assay for Type A Influenza Virus and the Avian H5 and H7 Hemagglutinin SubtypesJournal of Clinical Microbiology, 2002
- External Quality Assessment Program for Qualitative and Quantitative Detection of Hepatitis C Virus RNA in Diagnostic VirologyJournal of Clinical Microbiology, 2002
- Real-time PCR in virologyNucleic Acids Research, 2002
- High Degree of Interlaboratory Reproducibility of Human Immunodeficiency Virus Type 1 Protease and Reverse Transcriptase Sequencing of Plasma Samples from Heavily Treated PatientsJournal of Clinical Microbiology, 2001