Live/Real Time Three‐Dimensional Transthoracic Echocardiographic Assessment of Left Ventricular Volumes, Ejection Fraction, and Mass Compared with Magnetic Resonance Imaging
- 20 February 2007
- journal article
- research article
- Published by Wiley in Echocardiography
- Vol. 24 (2) , 166-173
- https://doi.org/10.1111/j.1540-8175.2006.00428.x
Abstract
Due to reliance upon geometric assumptions and foreshortening issues, the traditionally utilized transthoracic two-dimensional echocardiography (2DTTE) has shown limitations in assessing left ventricular (LV) volume, mass, and function. Cardiac magnetic resonance imaging (MRI) has shown potential in accurately defining these LV characteristics. Recently, the emergence of live/real time three-dimensional (3D) TTE has demonstrated incremental value over 2DTTE and comparable value with MRI in assessing LV parameters. Here we report 58 consecutive patients with diverse cardiac disorders and clinical characteristics, referred for clinical MRI studies, who were evaluated by cardiac MRI and 3DTTE. Our results show good correlation between the two modalities.Keywords
This publication has 20 references indexed in Scilit:
- Live/Real Time Three‐Dimensional Transthoracic Echocardiographic Assessment of Left Ventricular Volumes, Ejection Fraction, and Mass Compared with Magnetic Resonance ImagingEchocardiography, 2007
- Improved quantification of left ventricular mass based on endocardial and epicardial surface detection with real time three dimensional echocardiographyHeart, 2006
- Real-Time Transthoracic Three-Dimensional Echocardiographic Assessment of Left Ventricular Volume and Ejection Fraction in Congenital Heart DiseasePublished by Elsevier ,2006
- Three-Dimensional Echocardiography: Rational Mode of Component Images for Left Ventricular Volume QuantitationCardiology, 2005
- Comparison of Accurate Measurement of Left Ventricular Mass in Patients With Hypertrophied Hearts by Real-Time Three-Dimensional Echocardiography Versus Magnetic Resonance ImagingThe American Journal of Cardiology, 2005
- Rapid full volume data acquisition by real-time 3-dimensional echocardiography for assessment of left ventricular indexes in children: A validation study compared with magnetic resonance imagingJournal of the American Society of Echocardiography, 2005
- Comparison of left ventricular volumes and ejection fractions measured by three-dimensional echocardiography versus by two-dimensional echocardiography and cardiac magnetic resonance in patients with various cardiomyopathiesThe American Journal of Cardiology, 2005
- Fast Measurement of Left Ventricular Mass With Real-Time Three-Dimensional EchocardiographyCirculation, 2004
- Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiographyJournal of the American College of Cardiology, 2004
- Anatomic validation of a novel method for left ventricular volume and mass measurements with use of real-time 3-dimensional echocardiographyJournal of the American Society of Echocardiography, 2001