The Efficacy of Metallic Stent Placement in the Treatment of Colorectal Obstruction
Open Access
- 1 January 2002
- journal article
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 3 (2) , 79-86
- https://doi.org/10.3348/kjr.2002.3.2.79
Abstract
To evaluate the efficacy of newly designed covered and non-covered coated colorectal stents for colonic decompression. Twenty-six patients, (15 palliative cases and 11 preoperative) underwent treatment for the relief of colorectal obstruction using metallic stents positioned under fluoroscopic guidance. In 24 of the 26, primary colorectal carcinoma was diagnosed, and in the remaining two, recurrent colorectal carcinoma. Twenty-one patients were randomly selected to receive either a type A or type B stent; for the remaining five, type C was used. Type A, an uncovered nitinol wire stent, was lightly coated to ensure structural integrity. Type B (flare type) and C (shoulder type) stents were polyurethane covered and their diameter was 24 and 26mm, respectively. The rates of technical success, clinical success, and complications were analyzed using the chi-square test, and to analyse the mean period of patency, the Kaplan-Meier method was used. Thirty of 31 attempted placements in 26 patients were successful, with a technical success rate of 96.8% (30/31) and a clinical success rate of 80.0% (24/30). After clinically successful stent placement, bowel decompression occurred within 1-4 (mean, 1.58 ± 0.9) days. Five of six clinical failures involved stent migration and one stent did not expand after successful placement. In the preoperative group, 11 stents, one of which migrated, were placed in ten patients, in all of whom bowel preparation was successful. In the palliative group, 19 stents were placed in 15 patients. The mean period of patency was 96.25 ± 105.12 days: 146.25 ± 112.93 for type-A, 78.82 ± 112.26 for type-B, and 94.25 ± 84.21 for type-C. Complications associated with this procedure were migration (n=6, 20%), pain (n=4, 13.3%), minor bleeding (n=5, 16.7%), incomplete expansion (n=1, 3.3%), and tumor ingrowth (n=1, 3.3%). The migration rate was significantly higher in the type-B group than in other groups (p=0.038). Newly designed covered and non-covered metallic stents of a larger diameter are effective for the treatment of colorectal obstruction. The migration rate of covered stents with flaring is higher than that of other types. For evaluation of the ideal stent configuration for the relief of colorectal obstruction, a clinical study involving a larger patient group is warranted.Keywords
This publication has 15 references indexed in Scilit:
- Malignant Colorectal Obstruction Treated by Means of Self-expanding Metallic Stents: Effectiveness before Surgery and in PalliationRadiology, 2000
- Acute Colorectal Obstruction: Treatment with Self-expandable Metallic Stents before Scheduled Surgery—Results of a Multicenter StudyRadiology, 1999
- Acute colorectal obstruction: stent placement for palliative treatment--results of a multicenter study.Radiology, 1998
- Malignant colorectal obstruction: treatment with a flexible covered stent.Radiology, 1998
- Acute colonic obstruction: clinical aspects and cost-effectiveness of preoperative and palliative treatment with self-expanding metallic stents--a preliminary report.Radiology, 1998
- Treatment of colonic obstruction with expandable metal stents: radiologic features.American Journal of Roentgenology, 1997
- Stent endoprosthesis for obstructing colorectal cancersDiseases of the Colon & Rectum, 1996
- Surgical concepts in the treatment of colorectal cancerSeminars in Roentgenology, 1996
- Colorectal cancer: Etiologic and clinical aspectsSeminars in Roentgenology, 1996
- Self-expanding mesh stent for endoscopic palliation of rectal obstructing tumors: a preliminary reportSurgical Endoscopy, 1992