Continuous Passive Motion With Accelerated Flexion After Total Knee Arthroplasty
- 1 December 1997
- journal article
- clinical trial
- Published by Wolters Kluwer Health
- Vol. 345 (345) , 38???43-43
- https://doi.org/10.1097/00003086-199712000-00007
Abstract
The use of continuous passive motion after total knee arthroplasty remains controversial. A new approach, starting continuous passive motion at 70° to 100° flexion in the recovery room (Group I) was evaluated. A randomized, prospective study of 210 consecutive total knee arthroplasties was performed at two institutions. The control population (Group II) started continuous passive motion at 0° to 30°, and progressed toward 100° flexion. Flexion at postoperative Day 3 (Group I = 82.5°, Group II = 72.8°), and at discharge (Group I = 89.1°, Group II = 84.3°) were significantly different. There was no significant difference between the groups at 4 weeks (Group I = 5.0°-104.1°, Group II = 5.6°-102.0°), 6 weeks (Group I = 2.3°-104.8°, Group II = 2.7°-103.6°), 12 weeks (Group I = 1.7°-107.7°, Group II = 4.7°-108.2°), or at 1 year (Group I = 0.5°-113.2°, Group II = 1.8°-110.5°). In Group I, wound necrosis developed in one patient that required a gastrocnemius flap. This major complication was caused by a tight dressing, and not necessarily to the accelerated flexion continuous passive motion. This investigation shows that continuous passive motion using accelerated flexion allows increased flexion during the hospital stay without increased risk of complications, pain, or blood loss. This has significant implications for achieving safe, early discharge. However, no difference was found at followup of 4 weeks or greater, and this did not add significantly to the final outcome.Keywords
This publication has 8 references indexed in Scilit:
- Healing and remodeling of articular incongruities in a rabbit fracture model.Journal of Bone and Joint Surgery, 1993
- CONTINUOUS PASSIVE MOTION IN THE REHABILITATION SETTINGAmerican Journal of Physical Medicine & Rehabilitation, 1993
- Postoperative use of continuous passive motion, transcutaneous electrical nerve stimulation, and continuous cooling pad following total knee arthroplastyThe Journal of Arthroplasty, 1991
- Mechanical Measures in the Prophylaxis of Postoperative Thromboembolism in Total Knee ArthroplastyPublished by Wolters Kluwer Health ,1990
- No effect of continuous passive motion after arthroplasty of the kneeActa Orthopaedica, 1988
- Continuous passive motion after total knee arthroplastyThe Journal of Arthroplasty, 1987
- A Comparison of the Effects of Immobilization and Continuous Passive Motion on Surgical Wound Healing in Mature RabbitsPlastic and Reconstructive Surgery, 1986
- Continuous Passive Motion After Total Knee ArthroplastySouthern Medical Journal, 1986