Comparison of Output Particle Size Distributions from Pressurized Aerosols Formulated as Solutions or Suspensions
- 1 January 1988
- journal article
- research article
- Published by Springer Nature in Pharmaceutical Research
- Vol. 05 (1) , 36-39
- https://doi.org/10.1023/a:1015859311228
Abstract
The delivery of particles as small as possible (preferably <5 µm) to the respiratory tract should be the aim of those formulating metered dose inhalers (MDIs). This may be facilitated by the formulation of solution, rather than suspension-type, pressurized aerosol units. Two series of MDIs were compared; one contained suspended micronized disodium fluorescein (0.1%, w/v), while the other contained the same concentration of dissolved salicylic acid. Either oleic acid, L-α-phosphatidylcholine, or sorbitan trioleate was incorporated at 0.15% (w/v) as suspending agent (disodium fluorescein) or solubilizing agent (salicylic acid). The propellant blend was 70% (w/w) Freon 12 and 30% (w/w) Freon 11 in all cases. This exhibited a vapor pressure of 50.6 psig (444.7 kPa) at 21°C. The output particle size distribution of the aerosol reaching the cascade impactor showed a mass median aerodynamic diameter (MMAD) of approximately 4 and 2 µm for the suspension and solution formulations respectively, regardless of the surfactant used. Larger MMADs were observed for solution aerosols formulated with oleic acid (2.32 µm) compared to those containing L-α-phosphatidylcholine (1.93 µm) or sorbitan trioleate (2.07 µm). Possible reasons for these observations are discussed.This publication has 8 references indexed in Scilit:
- Prediction of Drug Residence Times in Regions of the Human Respiratory Tract Following Aerosol InhalationJournal of Pharmaceutical Sciences, 1986
- Effect of InspirEase on the Deposition of Metered-Dose Aerosols in the Human Respiratory TractChest, 1986
- Development of a systematic theory of suspension inhalation aerosols. I. A framework to study the effects of aggregation on the aerodynamic behaviour of drug particlesInternational Journal of Pharmaceutics, 1985
- Spacer Devices Used with Metered-Dose InhalersChest, 1985
- A semi-empirical model of aerosol deposition in the human respiratory tract for mouth inhalationJournal of Pharmacy and Pharmacology, 1981
- Fraction of dose exhaled after administration of pressurized inhalation aerosolsInternational Journal of Pharmaceutics, 1980
- Perspectives on the Biopharmacy of Inhalation AerosolsDrug Development and Industrial Pharmacy, 1978
- Variation in delivery of isoprenaline from various pressurized inhalers.1973