Respiratory comfort and breathing pattern during volume proportional assist ventilation and pressure support ventilation: A study on volunteers with artificially reduced compliance
- 1 June 2000
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 28 (6) , 1940-1946
- https://doi.org/10.1097/00003246-200006000-00042
Abstract
To assess respiratory comfort and associated breathing pattern during volume assist (VA) as a component of proportional assist ventilation and during pressure support ventilation (PSV). Prospective, double-blind, interventional study. Laboratory. A total of 15 healthy volunteers (11 females, 4 males) aged 21-31 yrs. Decreased respiratory system compliance was simulated by banding of the thorax and abdomen. Volunteers breathed via a mouthpiece with VA and PSV each applied at two levels (VA, 8 cm H2O/L and 12 cm H2O/L; PSV, 10 cm H2O and 15 cm H2O) using a positive end-expiratory pressure of 5 cm H2O throughout. The study was subdivided into two parts. In Part 1, volunteers breathed three times with each of the four settings for 2 mins in random order. In Part 2, the first breath effects of multiple, randomly applied mode, and level shifts were studied. In Part 1, the volunteers were asked to estimate respiratory comfort in comparison with normal breathing using a visual analog scale. In Part 2, they were asked to estimate the change of respiratory comfort as increased, decreased, or unchanged immediately after a mode shift. Concomitantly, the respiratory pattern (change) was characterized with continuously measured tidal volume, respiratory rate, pressure, and gas flow. Respiratory comfort during VA was higher than during PSV. The higher support level was less important during VA but had a major negative influence on comfort during PSV. Both modes differed with respect to the associated breathing pattern. Variability of breathing was higher during VA than during PSV (Part 1). Changes in respiratory variables were associated with changes in respiratory comfort (Part 2). For volunteers breathing with artificially reduced respiratory system compliance, respiratory comfort is higher with VA than with PSV. This is probably caused by a better adaptation of the ventilatory support to the volunteer's need with VA.Keywords
This publication has 20 references indexed in Scilit:
- Respiratory comfort of automatic tube compensation and inspiratory pressure support in conscious humansIntensive Care Medicine, 1997
- Effects of breathing route, temperature and volume of inspired gas, and airway anesthesia on the response of respiratory output to varying inspiratory flow.American Journal of Respiratory and Critical Care Medicine, 1996
- Comparison of breathing comfort during weaning with two ventilatory modes.American Journal of Respiratory and Critical Care Medicine, 1994
- Effect of Inspiratory Flow Rate on Respiratory Output in Normal SubjectsAmerican Review of Respiratory Disease, 1992
- Tidal volume, breathing frequency, and oxygen consumption at different pressure support levels in the early stage of weaning in patients without chronic obstructive polmonary diseaseIntensive Care Medicine, 1992
- Proportional Assist Ventilation, a New Approach to Ventilatory Support: TheoryAmerican Review of Respiratory Disease, 1992
- Cardiovascular, respiratory, and metabolic changes produced by pressure-supported ventilation in intensive care unit patientsCritical Care Medicine, 1989
- Respiratory Function during Pressure Support VentilationChest, 1986
- Effect of the cheeks and the compliance of alveolar gas on the measurement of respiratory variablesRespiration Physiology, 1982
- Totale Dehnbarkeit von Lunge und Thorax bei GesundenRespiration, 1974