Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission Tomography
- 1 September 1987
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 6 (3) , 228-238
- https://doi.org/10.1109/tmi.1987.4307831
Abstract
Images produced in emission tomography with the expectation-maximization algorithm have been observed to become more noisy and to have large distortions near edges as iterations proceed and the images converge towards the maximum-likelihood estimate. It is our conclusion that these artifacts are fundamental to reconstructions based on maximum-likelihood estimation as it has been applied usually; they are not due to the use of the expectation-maximization algorithm, which is but one numerical approach for finding the maximum-likelihood estimate. In this paper, we develop a mathematical approach for suppressing both the noise and edge artifacts by modifying the maximum-likelihood approach to include constraints which the estimate must satisfy.Keywords
This publication has 9 references indexed in Scilit:
- The Use of Sieves to Stabilize Images Produced with the EM Algorithm for Emission TomographyIEEE Transactions on Nuclear Science, 1985
- Maximum-Likelihood Reconstruction for Single-Photon Emission Computed-TomographyIEEE Transactions on Nuclear Science, 1985
- Precision bounds in superresolution processingJournal of the Optical Society of America A, 1984
- Image Reconstruction from List-Mode Data in an Emission Tomography System Having Time-of-Flight MeasurementsIEEE Transactions on Nuclear Science, 1983
- Super PETT I: A Positron Emission Tomograph Utilizing Photon Time-of-Flight InformationIEEE Transactions on Medical Imaging, 1982
- Maximum Likelihood Reconstruction for Emission TomographyIEEE Transactions on Medical Imaging, 1982
- A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight MeasurementsIEEE Transactions on Nuclear Science, 1981
- Photon Time-of-Flight-Assisted Positron Emission TomographyJournal of Computer Assisted Tomography, 1981
- SPECT: Single Photon Emission Computed TomographyIEEE Transactions on Nuclear Science, 1980