A novel approach for precise simulation of the EMG signal detected by surface electrodes
Top Cited Papers
- 1 June 2001
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 48 (6) , 637-646
- https://doi.org/10.1109/10.923782
Abstract
The authors propose a new electromyogram generation and detection model. The volume conductor is described as a nonhomogeneous (layered) and anisotropic medium constituted by muscle, fat and skin tissues. The surface potential detected in space domain is obtained from the application of a two-dimensional spatial filter to the input current density source. The effects of electrode configuration, electrode size and inclination of the fibers with respect to the detection system are included in the transfer function of the filter. Computation of the signal in space domain is performed by applying the Radon transform; this permits to draw considerations about spectral dips and clear misunderstandings in previous theoretical derivations. The effects of generation and extinction of the action potentials at the fiber end plate and at the tendons are included by modeling the source current, without any approximation of its shape, as a function of space and time and by using again the Radon transform. The approach, based on the separation of the temporal and spatial properties of the muscle fiber action potential and of the volume conductor, includes the capacitive tissue properties.Keywords
This publication has 37 references indexed in Scilit:
- Noninvasive estimation of motor unit conduction velocity distribution using linear electrode arraysIEEE Transactions on Biomedical Engineering, 2000
- Effect of electrode dimensions on motor unit potentialsMedical Engineering & Physics, 1999
- Modeling of surface myoelectric signals. II. Model-based signal interpretationIEEE Transactions on Biomedical Engineering, 1999
- Volume conduction models for surface EMG; confrontation with measurementsJournal of Electromyography and Kinesiology, 1997
- Improvement of spatial resolution in surface-EMG: a theoretical and experimental comparison of different spatial filtersIEEE Transactions on Biomedical Engineering, 1997
- Simulation of electromyographic signalsJournal of Electromyography and Kinesiology, 1993
- The spatial integration effect of surface electrode detecting myoelectric signalIEEE Transactions on Biomedical Engineering, 1992
- Finite limb dimensions and finite muscle length in a model for the generation of electromyographic signalsElectroencephalography and Clinical Neurophysiology/Evoked Potentials Section, 1991
- Influence of tissue inhomogeneities on noninvasive muscle fiber conduction velocity measurements-investigated by physical and numerical modelingIEEE Transactions on Biomedical Engineering, 1991
- Spatial and temporal frequency-dependent conductivities in volume-conduction calculations for skeletal muscleMathematical Biosciences, 1988