Reliability and Validity of the Omnitron Hydraulic Resistance Exercise and Testing Device
- 1 December 1989
- journal article
- research article
- Published by Georg Thieme Verlag KG in International Journal of Sports Medicine
- Vol. 10 (06) , 455-459
- https://doi.org/10.1055/s-2007-1024943
Abstract
This study assessed the measurement reliability and validity of the Hydra-Fitness Omnitron, a microprocessor-controlled isokinetic ergometer that provides concentric resistance for dynamic extension and flexion movements as well as resistance for isometric contractions. Maximal peak torque output measured by the Omnitron and strain gauge devices connected to the apparatus were compared in 26 physically active males who were tested over 3 days for isometric knee extension and isokinetic knee flexion/extension at two resistance levels. Maximal torque outputs remained stable on days 2 and 3 (p < 0.05), and in-traclass reliability yielded r = 0.94 to 0.98. There was no difference between the slopes of the regression lines for the different experimental conditions (p > 0.05). There was significant improvement between day 1 and days 2 and 3 that corresponded to a combination of a training and learning effect. Thus, one practice session was necessary to obtain reliable individual differences. The validity correlations between peak torque output measured from the Omnitron and strain gauges were greater than r = 0.94. There was a small discrepancy (0.44 to 0.88 Nm) between the two measuring devices that can be explained by the difference in shank pad positioning that accomodates for different segment lengths. We conclude that reliability and validity were excellent over a wide range of torque outputs measured during maximal isometric and maximal dynamic double concentric flexion and extension movements.Keywords
This publication has 9 references indexed in Scilit:
- ISOKINETIC STRENGTH TRAINING PROTOCOLS - DO THEY INDUCE SKELETAL-MUSCLE FIBER HYPERTROPHY1988
- The effects of hydraulic resistance strength training in pre-pubertal malesMedicine & Science in Sports & Exercise, 1986
- Analysis of the reliability and validity of the kinetic communicator exercise deviceMedicine & Science in Sports & Exercise, 1986
- Inheritance of Human Muscle Enzyme Adaptation to Isokinetic Strength TrainingHuman Heredity, 1986
- Muscle performance, morphology and metabolic capacity during strength training and detraining: A one leg modelEuropean Journal of Applied Physiology, 1983
- The nature of torque ???overshoot??? in Cybex isokinetic dynamometryMedicine & Science in Sports & Exercise, 1982
- Specificity of power improvements through slow and fast isokinetic trainingJournal of Applied Physiology, 1981
- Errors in the use of isokinetic dynamometersEuropean Journal of Applied Physiology, 1981
- Adaptations in skeletal muscle following strength trainingJournal of Applied Physiology, 1979