Measurement of Cardiac Output by Pulse Dye Densitometry Using Indocyanine Green
- 1 October 1997
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 87 (4) , 816-822
- https://doi.org/10.1097/00000542-199710000-00015
Abstract
Background: A new method for determining cardiac output (CO, l/min) using dye dilution combined with pulse dye densitometry (PDD), based on the principle of pulse oximetry, has been developed. The aim of the study was to determine the accuracy and precision of PDD by comparing it with the thermodilution method. Methods: A prospective study was performed in 22 patients having surgery who were monitored using a pulmonary arterial catheter. In addition to the catheter, a specially designed photodetector was placed on the nasal wing. Ten milliliters of ice-cold indocyanine green dissolved in a 5% glucose solution (0.5 mg/ml) was injected. The dye and thermal dilution curves were simultaneously measured to calculate CO. Three to six injections were performed before and after surgery. Paired data were assessed in absolute terms, and the percentage errors were calculated by the degree of agreement and compared at three levels of CO (low < or = 3.5 < medium < or = 6 < high) by analysis of variance. Results: The mean and SDs of the differences between dye and thermodilution CO were 0.16 +/- 0.80 l/min or 4.5 +/- 19.6% for 191 paired data. Measurement after surgery failed in one patient. The percentage error with low CO (9.3 +/- 19.3%) was greater (P < 0.05) than those obtained with other CO. Conclusions: Pulse dye densitometry could measure CO repeatedly in patients having major surgery with the same degree of accuracy as the thermodilution method; however, a considerable degree of error was observed in some patients.Keywords
This publication has 5 references indexed in Scilit:
- Clinical Evaluation of the Vigilance Continuous Cardiac Output/Svo2 Monitoring System in Patients Undergoing Cardiac SurgeryAnesthesiology, 1994
- Improvement of cardiac output estimation by the thermodilution method during mechanical ventilationIntensive Care Medicine, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Binding of Sulfobromophthalein (BSP) Sodium and Indocyanine Green (ICG) by Plasma 1 Lipoproteins.Experimental Biology and Medicine, 1966
- Simplified Method for Calculating Flow, Mean Circulation Time and Downslope from Indicator-Dilution CurvesExperimental Biology and Medicine, 1956