Evaluation of two methods for monitoring surface cleanliness—ATP bioluminescence and traditional hygiene swabbing
- 1 January 1999
- journal article
- research article
- Published by Wiley in Luminescence
Abstract
The minimum bacterial detection limits and operator reproducibility of the Biotrace Clean‐Trace™ Rapid Cleanliness Test and traditional hygiene swabbing were determined. Areas (100 cm2) of food grade stainless steel were separately inoculated with known levels of Staphylococcus aureus (NCTC 6571) and Escherichia coli (ATCC 25922). Surfaces were sampled either immediately after inoculation while still wet, or after 60 min when completely dry. For both organisms the minimum detection limit of the ATP Clean‐Trace™ Rapid Cleanliness Test was 104 cfu/100 cm2 (p < 0.05) and was the same for wet and dry surfaces. Both organism type and surface status (i.e. wet or dry) influenced the minimum detection limits of hygiene swabbing, which ranged from 102 cfu/100 cm2 to >107 cfu/100 cm2. Hygiene swabbing percentage recovery rates for both organisms were less than 0.1% for dried surfaces but ranged from 0.33% to 8.8% for wet surfaces. When assessed by six technically qualified operators, the Biotrace Clean‐Trace™ Rapid Cleanliness Test gave superior reproducibility for both clean and inoculated surfaces, giving mean coefficients of variation of 24% and 32%, respectively. Hygiene swabbing of inoculated surfaces gave a mean CV of 130%. The results are discussed in the context of hygiene monitoring within the food industry. Copyright © 1999 John Wiley & Sons, Ltd.Keywords
This publication has 6 references indexed in Scilit:
- Resuscitation of ‘non-culturable’ cells from aged cultures of Campylobacter jejuniMicrobiology, 1997
- The isolation of Campylobacter jejuni from contaminated surfaces and its survival in diluentsInternational Journal of Food Microbiology, 1995
- Adenosine Triphosphate Bioluminescence for Hygiene Monitoring in Health Care InstitutionsJournal of Food Protection, 1994
- Assessment of cleaning and disinfection in the food industry with the rapid ATP-bioluminescence technique combined with the tissue fluid contamination test and a conventional microbiological methodInternational Journal of Food Microbiology, 1993
- THE APPLICATION of ATP BIOLUMINESCENCE FOR the ASSESSMENT of MILK QUALITY and FACTORY HYGIENEJournal of Rapid Methods and Automation in Microbiology, 1992
- Listeria spp. in food processing, non-food and domestic environmentsFood Microbiology, 1989