Abstract
The maximum intensity projection (MIP) is a popularly used algorithm for display of MRA images, but its performance has not been rigorously analyzed before. In this paper, four measures are proposed for the performance of the MIP algorithm and the quality of images projected from three-dimensional (3-D) data, which are vessel voxel projection probability, vessel detection probability, false vessel probability, and vessel-tissue contrast-to-noise ratio (CNR). As side products, vessel-missing probability, vessel receiver operating characteristics (ROC's), and mean number of false vessels are also studied. Based on the assumptions that the intensities of vessel, tissue, and noise along a projection path are independent Gaussian, these measures are derived and obtained all in closed forms. All the measures are functions of explicit parameters: vessel-to-tissue noise ratio (VTNR) and CNR of 3-D data prior to the MIP, vessel diameter, and projection length. It is shown that the MIP algorithm increases the CNR of large vessels whose CNR prior to the MIP is high and whose diameters are large. The increase in CNR increases with projection path length. On the other hand, all the proposed measures indicate that the small vessels that have low CNR prior to the MIP and small diameters suffer from the MIP. The performance gets worse as projection path length increases. All measures demonstrate a better performance when the vessel diameter is larger. Other properties and possible applications of the derived measures are also discussed.Keywords
This publication has 29 references indexed in Scilit:
- Small vessel enhancement in MRA images using local maximum mean processingIEEE Transactions on Image Processing, 2001
- Vessel enhancement filtering in three-dimensional MR angiography.Journal of Magnetic Resonance Imaging, 1995
- Statistically defined backgrounds:performance of a modified nonprewhitening observer modelJournal of the Optical Society of America A, 1994
- Gadolinium‐enhanced high‐resolution MR angiography with adaptive vessel tracking: Preliminary results in the intracranial circulationJournal of Magnetic Resonance Imaging, 1992
- Ideal versus human observer for long-tailed point spread functions: does deconvolution help?Physics in Medicine & Biology, 1991
- Visual signal detection IV Observer inconsistencyJournal of the Optical Society of America A, 1988
- An Introduction to Signal Detection and EstimationPublished by Springer Nature ,1988
- Addition of a channel mechanism to the ideal-observer modelJournal of the Optical Society of America A, 1987
- Hotelling trace criterion and its correlation with human-observer performanceJournal of the Optical Society of America A, 1987
- Radiographic Applications of Signal Detection TheoryRadiology, 1972