The measurement of whole body water by H218O dilution in newborn pigs
Open Access
- 1 April 1985
- journal article
- research article
- Published by Elsevier in The American Journal of Clinical Nutrition
- Vol. 41 (4) , 801-809
- https://doi.org/10.1093/ajcn/41.4.801
Abstract
Whole body water was measured in newborn piglets by isotope dilution with H218O. The results were compared with those obtained by direct analysis of whole body water made by freeze-drying. When the tracer dose of H218O was given to 30 piglets by intragastric gavage, post-equilibration values measured in urine were highly variable (average equilibration error equalled 9%) and the random error of the technique in predicting body water was 13%. When the dose was given to 49 animals intravenously, the post-equilibration values in urine were less variable (equilibration error equalled 4%), the random error of the technique was 7%, and body water was overestimated by 2%. The random error was reduced to 6% if data from animals in which equilibration errors exceeded 10% were excluded. When 18O enrichment in plasma instead of urine was measured, the technique was less precise (random error 11%). The estimation of body water from H218O overestimates body water by 2%. Isotope dilution with 18O is a safe, accurate and repeatable method for the estimation of whole body water, and is suitable for use in adult and newborn humans.This publication has 22 references indexed in Scilit:
- Determination of amino acid requirements of young pigs using an indicator amino acidBritish Journal of Nutrition, 1983
- Evaluation of the partitioning of bound inorganic phosphate during medium and intermediate phosphate in equilibrium water oxygen exchange reactions of yeast inorganic pyrophosphatase.Proceedings of the National Academy of Sciences, 1978
- Kinetics of the exchange of oxygen between carbon dioxide and carbonate in aqueous solutionThe Journal of Physical Chemistry, 1975
- Antipyrine Space Studies and Cell Water Estimates in Infants of Low Birth WeightPediatric Research, 1971
- The use of tritiated water, 4-aminoantipyrene andN-acetyl-4-aminoantipyrene for the measurement of body water in living pigsBritish Journal of Nutrition, 1966
- Measurement of Total Body Water with Deuterium Oxide and AntipyrineActa Physiologica Scandinavica, 1955
- Variation of O18 content of waters from natural sourcesGeochimica et Cosmochimica Acta, 1953
- THE MEASUREMENT OF TOTAL BODY WATER IN THE HUMAN SUBJECT BY DEUTERIUM OXIDE DILUTIONJournal of Clinical Investigation, 1950
- Chemical Composition of Newly Born MammalsNature, 1950
- Determination of Total Body Water and Solids With IsotopesScience, 1946