Effect of stimulation rate on phoneme recognition by Nucleus-22 cochlear implant listeners
- 1 January 2000
- journal article
- research article
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 107 (1) , 589-597
- https://doi.org/10.1121/1.428325
Abstract
This study investigated the effect of pulsatile stimulation rate on medial vowel and consonant recognition in cochlear implant listeners. Experiment 1 measured phoneme recognition as a function of stimulation rate in six Nucleus-22 cochlear implant listeners using an experimental four-channel continuous interleaved sampler (CIS) speech processing strategy. Results showed that all stimulation rates from 150 to 500 pulses/s/electrode produced equally good performance, while stimulation rates lower than 150 pulses/s/electrode produced significantly poorer performance. Experiment 2 measured phoneme recognition by implant listeners and normal-hearing listeners as a function of the low-pass cutoff frequency for envelope information. Results from both acoustic and electric hearing showed no significant difference in performance for all cutoff frequencies higher than 20 Hz. Both vowel and consonant scores dropped significantly when the cutoff frequency was reduced from 20 Hz to 2 Hz. The results of these two experiments suggest that temporal envelope information can be conveyed by relatively low stimulation rates. The pattern of results for both electrical and acoustic hearing is consistent with a simple model of temporal integration with an equivalent rectangular duration (ERD) of the temporal integrator of about 7 ms.Keywords
This publication has 22 references indexed in Scilit:
- Pseudospontaneous activity: stochastic independence of auditory nerve fibers with electrical stimulationHearing Research, 1999
- Effects of amplitude nonlinearity on phoneme recognition by cochlear implant users and normal-hearing listenersThe Journal of the Acoustical Society of America, 1998
- Speech Recognition as a Function of the Number of Electrodes Used in the SPEAK Cochlear Implant Speech ProcessorJournal of Speech, Language, and Hearing Research, 1997
- Detection of decrements and increments in sinusoids at high overall levelsThe Journal of the Acoustical Society of America, 1996
- The perceptual dimensions of single-electrode and nonsimultaneous dual-electrode stimuli in cochlear implanteesThe Journal of the Acoustical Society of America, 1996
- Melody recognition and musical interval perception by deaf subjects stimulated with electrical pulse trains through single cochlear implant electrodesThe Journal of the Acoustical Society of America, 1995
- Acoustic characteristics of American English vowelsThe Journal of the Acoustical Society of America, 1995
- Effect of temporal envelope smearing on speech receptionThe Journal of the Acoustical Society of America, 1994
- Temporal information in speech: acoustic, auditory and linguistic aspectsPhilosophical Transactions Of The Royal Society B-Biological Sciences, 1992
- An Analysis of Perceptual Confusions Among Some English ConsonantsThe Journal of the Acoustical Society of America, 1955