Factors affecting the region of most isometric femoral attachments
- 1 March 1989
- journal article
- research article
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 17 (2) , 208-216
- https://doi.org/10.1177/036354658901700210
Abstract
During flexion of the intact knee, we measured the changes in distance between possible tibial and femoral attachments of an intraarticular ACL substitute. The change in distance during motion was described by the difference between the longest and shortest distances measured. Using knees from eight cadaver donors, we studied the effects of varying tibial and femoral attach ment locations, applying anterior and posterior forces, and altering the range of flexion. We found that altering the femoral attachment had a much larger effect than had altering the tibial attach ment. No femoral attachments were completely iso metric. Femoral attachments that produced the small est change in tibiofemoral distance, 2 mm and less, formed a band whose greatest width ranged from 3 to 5 mm. The axis of the 2 mm region was nearly proximal- distal in orientation and located near the center of the ACL's femoral insertion. Attachments located anterior to the axis moved away from the tibial attachment with flexion, whereas attachments located posterior to the axis moved toward the tibia. The AP position of the tibial attachment affected the orientation of the 2 mm region. Moving the tibial attach ment posteriorly caused the proximal part of the region to move anterior, with little change in the location of the distal part of the region. Changing the applied joint force from anterior to posterior was similar to moving the tibial attachment posteriorly, but the effect was less pronounced. Increasing the range of flexion from 90° to 120° caused the 2 mm region to become narrower and changed its orientation.This publication has 40 references indexed in Scilit:
- Factors affecting the region of most isometric femoral attachmentsThe American Journal of Sports Medicine, 1989
- Sensitivity of Insertion Locations on Length Patterns of Anterior Cruciate Ligament FibersJournal of Biomechanical Engineering, 1986
- Bony Entrapment of the Superficial Peroneal NerveClinical Orthopaedics and Related Research, 1984
- Optimization of knee ligament position for lateral extraarticular reconstructionThe American Journal of Sports Medicine, 1983
- The Lateral Pivot ShiftClinical Orthopaedics and Related Research, 1980
- Roentgen stereophotogrammetric methods for the evaluation of the three dimensional kinematic behaviour and cruciate ligament length patterns of the human knee jointJournal of Biomechanics, 1979
- A technique for calculating in vivo ligament lengths with application to the human knee jointJournal of Biomechanics, 1978
- Strain Gauge Analysis of Knee LigamentsPublished by Wolters Kluwer Health ,1977
- An analytical model of the kneeJournal of Biomechanics, 1976
- Artificial Ligaments at the KneeNew England Journal of Medicine, 1934