The Pressure Measured in Ophthalmodynamometry
- 1 March 1972
- journal article
- research article
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 87 (3) , 290-292
- https://doi.org/10.1001/archopht.1972.01000020292011
Abstract
The pressure determined in ophthalmodynamometry is not the local pressure in the central retinal artery, but rather the pressure somewhere in the much larger ophthalmic artery. Using a steady flow analysis, this communication mathematically determines (1) the site corresponding to the systolic dynamometric pressure, and (2) the actual central retinal artery pressure before the ophthalmodynamometry was performed. The systolic pressure determined by ophthalmodynamometry is shown to be 14 to 17 mm Hg higher than the normal central retinal artery systolic pressure. The magnitude of this discrepancy is due primarily to the small lumen of the central retinal artery, which produces a very large pressure gradient.Keywords
This publication has 8 references indexed in Scilit:
- Uveal Circulation, a Review of Methods and ResultsPublished by S. Karger AG ,2015
- Retinal Blood FlowPublished by Springer Nature ,2007
- Intraocular Pressure and OphthalmodynamometryArchives of Ophthalmology (1950), 1965
- Retinal Oxygen Utilization Measured by Hyperbaric BlackoutArchives of Ophthalmology (1950), 1964
- Arteries of the orbit in the human beingBritish Journal of Surgery, 1963
- Modern ophthalmodynamometryDocumenta Ophthalmologica, 1959
- Retinal Vascular DynamicsAmerican Journal of Ophthalmology, 1934
- THE OCULAR CIRCULATION: ITS NORMAL PRESSURE RELATIONSHIPS AND THEIR PHYSIOLOGICAL SIGNIFICANCEBritish Journal of Ophthalmology, 1926