Amino Acid Analysis by Capillary Electrophoresis Electrospray Ionization Mass Spectrometry
Top Cited Papers
- 18 February 2000
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 72 (6) , 1236-1241
- https://doi.org/10.1021/ac990976y
Abstract
A method for the determination of underivatized amino acids based on capillary electrophoresis coupled to electrospray ionization mass spectrometry (CE−ESI-MS) is described. To analyze free amino acids simultaneously a low acidic pH condition was used to confer positive charge on whole amino acids. The choice of the electrolyte and its concentration influenced resolution and peak shape of the amino acids, and 1 M formic acid was selected as the optimal electrolyte. Meanwhile, the sheath liquid composition had a significant effect on sensitivity and the highest sensitivity was obtained when 5 mM ammonium acetate in 50% (v/v) methanol−water was used. Protonated amino acids were roughly separated by CE and selectively detected by a quadrupole mass spectrometer with a sheath flow electrospray ionization interface. Under the optimized conditions, 19 free amino acids normally found in proteins and several physiological amino acids were well determined in less than 17 min. The detection limits for basic amino acids were between 0.3 and 1.1 μmol/L and for acidic and low molecular weight amino acids were less than 6.0 μmol/L with pressure injection of 50 mbar for 3 s (3 nL) at a signal-to-noise ratio of 3. This method is simple, rapid, and selective compared with conventional techniques and could be readily applied to the analysis of free amino acids in soy sauce.Keywords
This publication has 24 references indexed in Scilit:
- Determination of small carboxylic acids by capillary electrophoresis with electrospray-mass spectrometryAnalytica Chimica Acta, 1999
- Analyses of phenolic compounds by capillary electrophoresis electrospray mass spectrometryRapid Communications in Mass Spectrometry, 1999
- Improvements in LC/Electrospray Ion Trap Mass Spectrometry Performance Using an Off-Axis NebulizerAnalytical Chemistry, 1999
- FDA, Reform, and the Well-Characterized BiologicAnalytical Chemistry, 1996
- Chiral Separation and Detection of Terbutaline and Ephedrine by Capillary Electrophoresis Coupled with Ion Spray Mass SpectrometryAnalytical Chemistry, 1995
- Use of 3-(p-carboxybenzoyl)quinoline-2-carboxaldehyde to label amino acids for high-sensitivity fluorescence detection in capillary electrophoresisAnalytica Chimica Acta, 1995
- Liquid Sheath Effects on the Separation of Proteins in Capillary Electrophoresis/Electrospray Mass SpectrometryAnalytical Chemistry, 1994
- Gel-filled capillary electrophoresis/mass spectrometry using a liquid junction ion spray interfaceAnalytical Chemistry, 1992
- Fluorescence detection in capillary electrophoresis: evaluation of derivatizing reagents and techniquesAnalytical Chemistry, 1991
- Amino Acid Profiling of Protein Hydrolysates Using Liquid Chromatography and Fluorescence DetectionJournal of Liquid Chromatography, 1979