Three-Way Multivariate Calibration Procedures Applied To High-Performance Liquid Chromatography Coupled with Fast-Scanning Fluorescence Spectrometry Detection. Determination of Polycyclic Aromatic Hydrocarbons in Water Samples
- 24 March 1998
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 70 (9) , 1949-1955
- https://doi.org/10.1021/ac970939b
Abstract
Three-way partial least-squares and n factor parallel factor analysis have been compared for the analysis of polycyclic aromatic hydrocarbons in water samples. Data were obtained with a chromatographic system set to record short-time chromatograms containing several unresolved peaks. The detection system consisted of a fast-scanning fluorescence spectra detector, which allows one to obtain three-dimensional data, where retention time, emission wavelengths, and fluorescence intensity are represented. The combined use of a multivariate calibration method and the three-dimensional data obtained from the HPLC−FSFS system allows resolution of closely eluting compounds, thus making a complete separation unnecessary. The procedure has been applied to tap water samples (spiked at 0.10 and 0.20 μg L-1 levels) with good results, similar to those obtained with a HPLC system with a conventional fluorescence detector.Keywords
This publication has 29 references indexed in Scilit:
- Optimization of An On-Line Precolumn Preconcentration Method for the Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Water Samples (River and Sea Water)Analytical Letters, 1996
- Single-Measurement Excitation/Emission Matrix Spectrofluorometer for Determination of Hydrocarbons in Ocean Water. 2. Calibration and Quantitation of Naphthalene and StyreneAnalytical Chemistry, 1996
- Eigenstructure tracking analysis for assessment of peak purity in high-performance liquid chromatography with diode array detectionAnalytica Chimica Acta, 1995
- Parallel Kalman filters for peak purity analysis: extensions to non-ideal detector responseAnalytica Chimica Acta, 1995
- Identification of stereoisomeric benzo[a]pyrene tetrols by reversed-phase liquid chromatography coupled semi-ondashline to fluorescence line-narrowing spectroscopyAnalytica Chimica Acta, 1995
- Effects of resolution, peak ratio and sampling frequency in diode-array fluorescence detection in liquid chromatographyAnalytica Chimica Acta, 1993
- Exposure to carcinogenic PAHs in the environmentEnvironmental Science & Technology, 1992
- The Combination of Laser-Induced Fluorescence and Intensified Linear Diode Array Detection in Column Liquid ChromatographyAnalytical Letters, 1990
- Miniature fluorometric photodiode array detection system for capillary chromatographyAnalytical Chemistry, 1985
- Multicomponent self-modelling curve resolution in high-performance liquid chromatography by iterative target transformation analysisAnalytica Chimica Acta, 1985