Positron Emission Tomographic Measurement of Cerebral Blood Flow and Permeability—Surface Area Product of Water Using [15O]Water and [11C]Butanol
Open Access
- 1 October 1987
- journal article
- research article
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 7 (5) , 527-542
- https://doi.org/10.1038/jcbfm.1987.102
Abstract
We have previously adapted Kety's tissue autoradiographic method for measuring regional CBF in laboratory animals to the measurement of CBF in humans with positron emission tomography (PET) and H215O. Because this model assumes diffusion equilibrium between tissue and venous blood, the use of a diffusion-limited tracer, such as H215O, may lead to an underestimation of CBF. We therefore validated the use of [11C]butanol as an alternative freely diffusible tracer for PET. We then used it in humans to determine the underestimation of CBF that occurs with H215O, and thereby were able to calculate the extraction Ew and permeability–surface area product PSw of H215O. Measurements of the permeability of rhesus monkey brain to [11C]butanol, obtained by means of an intracarotid injection, external detection technique, demonstrated that this tracer is freely diffusible up to a CBF of at least 170 ml/min-100 g. CBF measured in baboons with the PET autoradiographic method and [11C]butanol was then compared with CBF measured in the same animals with a standard residue detection method. An excellent correspondence was obtained between both of these measurements. Finally, paired PET measurements of CBF were made with both H215O and [11C]butanol in 17 normal human subjects. Average global CBF was significantly greater when measured with [11C]butanol (53.1 ml/min-100 g) than with H215O (44.4 ml/min-100 g). Average global Ew was 0.84 and global PSw was 104 ml/min-100 g. Regional measurements showed a linear relationship between local PSw and CBF, while Ew was relatively uniform throughout the brain. Simulations were used to determine the potential error associated with the use of an incorrect value for the brain–blood partition coefficient for [11C]butanol and to calculate the effect of tissue heterogeneity and errors in flow measurement on the calculation of PSw.This publication has 60 references indexed in Scilit:
- QUANTITATIVE ANATOMY OF THE CEREBRAL VASCULAR BED WITH ESPECIAL EMPHASIS ON HOMOGENEITY AND INHOMOGENEITY IN SMALL PARTS OF THE GRAY AND WHITE MATTERActa Neurologica Scandinavica, 2009
- Cerebral Blood Flow with the Continuous Infusion of Oxygen-15-Labeled WaterJournal of Cerebral Blood Flow & Metabolism, 1985
- Synthesis of 15O-labeled butanol via organoborane chemistryThe International Journal of Applied Radiation and Isotopes, 1985
- Regional cerebral blood flow: Estimation by means of nonmetabolized diffusible tracers—An overviewSeminars in Nuclear Medicine, 1985
- Carbon-11-labeled 4-isopropylantipyrine: preparation and biological evaluation as a blood flow tracer in positron emission tomography (PET)Journal of Medicinal Chemistry, 1985
- 11C-Iodoantipyrine for the measurement of regional cerebral blood flow by positron emission tomography. Validation studies.Stroke, 1981
- Comparison of radio-labeled butanol and iodoantipyrine as cerebral blood flow markersBrain Research, 1981
- Simultaneous Measurement of Cerebral Blood Flow and Unidirectional Movement of Substances Across the Blood‐Brain Barrier: Theory, Method, and Application to LeucineJournal of Neurochemistry, 1981
- Regional brain blood flow in the conscious gerbil.Stroke, 1978
- The interpretation of mean transit time measurements for multiphase tissue systemsJournal of Theoretical Biology, 1973