Comparison of Measurements of Atmospheric Wet Delay by Radiosonde, Water Vapor Radiometer, GPS, and VLBI
- 1 June 2001
- journal article
- Published by American Meteorological Society in Journal of Atmospheric and Oceanic Technology
- Vol. 18 (6) , 830-850
- https://doi.org/10.1175/1520-0426(2001)018<0830:comoaw>2.0.co;2
Abstract
The accuracy of the Global Positioning System (GPS) as an instrument for measuring the integrated water vapor content of the atmosphere has been evaluated by comparison with concurrent observations made over a 14-day period by radiosonde, microwave water vapor radiometer (WVR), and Very Long Baseline Interferometry (VLBI). The Vaisala RS-80 A-HUMICAP radiosondes required a correction to the relative humidity readings (provided by Vaisala) to account for packaging contamination; the WVR data required a correction in order to be consistent with the wet refractivity formulation of the VLBI, GPS, and radiosondes. The best agreement of zenith wet delay (ZWD) among the collocated WVR, radiosondes, VLBI, and GPS was for minimum elevations of the GPS measurements below 10°. After corrections were applied to the WVR and radiosonde measurements, WVR, GPS, and VLBI (with 5° minimum elevation angle cutoff) agreed within ∼6 mm of ZWD [1 mm of precipitable water vapor (PWV)] when the differences were averaged,... Abstract The accuracy of the Global Positioning System (GPS) as an instrument for measuring the integrated water vapor content of the atmosphere has been evaluated by comparison with concurrent observations made over a 14-day period by radiosonde, microwave water vapor radiometer (WVR), and Very Long Baseline Interferometry (VLBI). The Vaisala RS-80 A-HUMICAP radiosondes required a correction to the relative humidity readings (provided by Vaisala) to account for packaging contamination; the WVR data required a correction in order to be consistent with the wet refractivity formulation of the VLBI, GPS, and radiosondes. The best agreement of zenith wet delay (ZWD) among the collocated WVR, radiosondes, VLBI, and GPS was for minimum elevations of the GPS measurements below 10°. After corrections were applied to the WVR and radiosonde measurements, WVR, GPS, and VLBI (with 5° minimum elevation angle cutoff) agreed within ∼6 mm of ZWD [1 mm of precipitable water vapor (PWV)] when the differences were averaged,...Keywords
This publication has 34 references indexed in Scilit:
- Improved 20‐ to 32‐GHz atmospheric absorption modelRadio Science, 1998
- Earth rotation measurement yields valuable information about the dynamics of the Earth systemEos, 1998
- Estimating horizontal gradients of tropospheric path delay with a single GPS receiverJournal of Geophysical Research, 1998
- Effects of atmospheric azimuthal asymmetry on the analysis of space geodetic dataJournal of Geophysical Research, 1997
- GPS surveying with 1 mm precision using corrections for atmospheric slant path delayGeophysical Research Letters, 1997
- The Promise of GPS in Atmospheric MonitoringBulletin of the American Meteorological Society, 1996
- GPS Meteorology: Mapping Zenith Wet Delays onto Precipitable WaterJournal of Applied Meteorology and Climatology, 1994
- GPS meteorology: Remote sensing of atmospheric water vapor using the global positioning systemJournal of Geophysical Research: Atmospheres, 1992
- Geodesy by radio interferometry: Effects of atmospheric modeling errors on estimates of baseline lengthRadio Science, 1985
- Comparison of geodetic and radio interferometric measurements of the Haystack‐Westford base line vectorJournal of Geophysical Research, 1980