Thresholds for inertial cavitation in Albunex suspensions under pulsed ultrasound conditions
- 1 January 2001
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 48 (1) , 161-170
- https://doi.org/10.1109/58.895927
Abstract
Stabilized microbubbles used as echo-contrast agents can be destroyed by ultrasonic irradiation. We have identified two pressure thresholds at which these microbubbles undergo inertial cavitation (here, defined as the collapse of gas bubbles followed by emission of an acoustic broadband noise). The first threshold (P1) corresponds to the pressure at which all the microbubbles in a cavitation field lose their property as an effective scatterer because of fragmentation or deflation. The second threshold (P2) is associated with the acoustic reactivation of the remnants of the contrast agents and is related to the onset of more violent inertial cavitation. P1 and P2 were measured as a function of the concentration of Albunex(R) (Molecular Biosystems Inc., San Diego, CA) contrast agent, the number of transmitting acoustic cycles, and the pulse repetition frequency (PRF). The ultrasound frequency used was 1.1 MHz, and the peak negative acoustic pressures ranged from 0 to 8 MPa. Our results, measured in Isoton(R) II (Coulter Diagnostics, Miami, FL) and whole blood solutions, showed that P1 increased with increasing Albunex(R) concentration and decreased with increasing PRF, whereas P2 decreased with increasing Albunex(R) concentration and was independent of the PRF. Both P1 and P2 decreased with increasing number of acoustic cycles N for N10. Ultrasound images of Albunex(R) acquired by a commercial scanner showed echo enhancement not only at pressure levels below P1 but also at levels above P2. The threshold P2 was achieved at ultrasound energies above the diagnostic level. Inertial cavitation produced at P2 was associated with a higher level of hemolysis compared with P1. The results of this investigation have potential significance for both diagnostic and therapeutic ultrasound applications.Keywords
This publication has 39 references indexed in Scilit:
- Acoustically Active Lipospheres Containing PaclitaxelInvestigative Radiology, 1998
- Broadband through-transmission signal loss measurements of Albunex® suspensions at concentrations approaching in vivo dosesThe Journal of the Acoustical Society of America, 1997
- Increased ultrasound contrast and decreased microbubble destruction rates with triggered ultrasound imagingJournal of the American Society of Echocardiography, 1996
- A cost effective degassing system for use in ultrasonic measurements: The multiple pinhole degassing systemThe Journal of the Acoustical Society of America, 1996
- Experimental observation of subharmonic oscillations in Infoson bubblesThe Journal of the Acoustical Society of America, 1996
- Effect of a Stabilized Microbubble Echo Contrast Agent on Hemolysis of Human Erythrocytes Exposed to High Intensity Pulsed UltrasoundEchocardiography, 1995
- Simulated capillary blood flow measurement using a nonlinear ultrasonic contrast agentUltrasonic Imaging, 1992
- Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environmentThe Journal of the Acoustical Society of America, 1990
- An acoustic backscattering technique for the detection of transient cavitation produced by microsecond pulses of ultrasoundThe Journal of the Acoustical Society of America, 1990
- Acoustic cavitation predictionThe Journal of the Acoustical Society of America, 1981