Evaluation of shoulder movement as a command control source
- 1 January 1990
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 37 (9) , 876-885
- https://doi.org/10.1109/10.58598
Abstract
The use of scapular shoulder movement as a command control source is evaluated. The focus is on the evaluation of movement signals from quadriplegic subjects as well as on the processing of these signals for use as command inputs to a functional neuromuscular stimulation (FNS) hand-grasp system. The shoulder movement of three C5-level quadriplegic and nine normal subjects was studied using externally mounted two-degree-of-freedom transducers overlying the sternum and clavicles. The C5-level quadriplegic subjects tested had a considerably poorer range of motion than the normal subjects. The range of motion was greatest in elevation but was coupled with a significant component of retraction. The vertical command resolution of the quadriplegic subjects range from 8 to 13 command levels, whereas the horizontal range contained four or fewer command levels. The quadriplegic subjects performed poorly in tasks where they were required to move to a point along the horizontal or vertical central axis and then along the opposite axis.Keywords
This publication has 8 references indexed in Scilit:
- A flexible, portable system for neuromuscular stimulation in the paralyzed upper extremityIEEE Transactions on Biomedical Engineering, 1988
- Sensors for Use with Functional Neuromuscular StimulationIEEE Transactions on Biomedical Engineering, 1986
- Design and Implementation of an Implantable GoniometerIEEE Transactions on Biomedical Engineering, 1986
- Closed Loop Control For Restoration of Movement in Paralyzed MusclePublished by SLACK, Inc. ,1984
- Myoelectric Signal Processing: Optimal Estimation Applied to Electromyography - Part II: Experimental Demonstration of Optimal Myoprocessor PerformanceIEEE Transactions on Biomedical Engineering, 1980
- Controlled prehension and release in the C5 quadriplegic elicited by functional electrical stimulation of the paralyzed forearm musculatureAnnals of Biomedical Engineering, 1980
- Myoelectric Signal Processing: Optimal Estimation Applied to Electromyography - Part I: Derivation of the Optimal MyoprocessorIEEE Transactions on Biomedical Engineering, 1980
- A Two-Axis Shoulder Position Transducer for Control of Orthotic/Prosthetic DevicesIEEE Transactions on Industrial Electronics and Control Instrumentation, 1972