Dobutamine stress echocardiography versus quantitative technetium-99m sestamibi SPECT for detecting residual stenosis and multivessel disease after myocardial infarction
Open Access
- 1 November 2001
- Vol. 86 (5) , 510-515
- https://doi.org/10.1136/heart.86.5.510
Abstract
OBJECTIVE To compare the relative accuracy of dobutamine stress echocardiography (DSE) and quantitative technetium-99m sestamibi single photon emission computed tomography (mibi SPECT) for detecting infarct related artery stenosis and multivessel disease early after acute myocardial infarction. DESIGN Prospective study. SETTING University hospital. METHODS 75 patients underwent simultaneous DSE and mibi SPECT at (mean (SD)) 5 (2) days after a first acute myocardial infarct. Quantitative coronary angiography was performed in all patients after imaging studies. RESULTS Significant stenosis (> 50%) of the infarct related artery was detected in 69 patients. Residual ischaemia was identified by DSE in 55 patients and by quantitative mibi SPECT in 49. The sensitivity of DSE and mibi SPECT for detecting significant infarct related artery stenosis was 78% and 70%, respectively, with a specificity of 83% for both tests. The combination of DSE and mibi SPECT did not change the specificity (83%) but increased the sensitivity to 94%. Mibi SPECT was more sensitive than DSE for detecting mild stenosis (73% v9%; p = 0.008). The sensitivity of DSE for detecting moderate or severe stenosis was greater than mibi SPECT (97%v 74%; p = 0.007). Wall motion abnormalities with DSE and transient perfusion defects with mibi SPECT outside the infarction zone were sensitive (80%v 67%; NS) and highly specific (95%v 93%; NS) for multivessel disease. CONCLUSIONS DSE and mibi SPECT have equivalent accuracy for detecting residual infarct related artery stenosis of ⩾ 50% and multivessel disease early after acute myocardial infarction. DSE is more predictive of moderate or severe infarct related artery stenosis. Combined imaging only improves the detection of mild stenosis.Keywords
This publication has 22 references indexed in Scilit:
- Safety and Accuracy of Dobutamine-Atropine Stress Echocardiography for the Detection of Residual Stenosis of the Infarct-Related Artery and Multivessel Disease During the First Week After Acute Myocardial InfarctionCirculation, 1997
- A Randomized Trial of Immediate versus Delayed Elective Angioplasty after Intravenous Tissue Plasminogen Activator in Acute Myocardial InfarctionNew England Journal of Medicine, 1987
- Usefulness of residual ischemic myocardium within prior infarct zone for identifying patients at high risk late after acute myocardial infarctionThe American Journal of Cardiology, 1987
- Echocardiographic prediction of the site of coronary artery obstruction in acute myocardial infarctionEuropean Heart Journal, 1987
- Predicting the extent and location of coronary artery disease in acute myocardial infarction by echocardiography during dobutamine infusionThe American Journal of Cardiology, 1986
- Coronary angiographic morphology in myocardial infarction: A link between the pathogenesis of unstable angina and myocardial infarctionJournal of the American College of Cardiology, 1985
- Does Visual Interpretation of the Coronary Arteriogram Predict the Physiologic Importance of a Coronary Stenosis?New England Journal of Medicine, 1984
- Prediction of cardiac events after uncomplicated myocardial infarction: a prospective study comparing predischarge exercise thallium-201 scintigraphy and coronary angiography.Circulation, 1983
- Limited Exercise Testing Soon After Myocardial InfarctionAnnals of Internal Medicine, 1981
- Noninvasive assessment of coronary stenoses by myocardial perfusion imaging during pharmacologie coronary vasodilatationThe American Journal of Cardiology, 1978