A sensitive, versatile microfluidic assay for bacterial chemotaxis
- 18 April 2003
- journal article
- research article
- Published by Proceedings of the National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 100 (9) , 5449-5454
- https://doi.org/10.1073/pnas.0931258100
Abstract
We have developed a microfluidic assay for bacterial chemotaxis in which a gradient of chemoeffectors is established inside a microchannel via diffusion between parallel streams of liquid in laminar flow. The random motility and chemotactic responses to l-aspartate, l-serine, l-leucine, and Ni2+ of WT and chemotactic-mutant strains of Escherichia coli were measured. Migration of the cells was quantified by counting the cells accumulating in each of 22 outlet ports. The sensitivity of the assay is attested to by the significant response of WT cells to 3.2 nM l-aspartate, a concentration three orders of magnitude lower than the detection limit in the standard capillary assay. The response to repellents was as robust and easily recorded as the attractant response. A surprising discovery was that l-leucine is sensed by Tar as an attractant at low concentrations and by Tsr as a repellent at higher concentrations. This assay offers superior performance and convenience relative to the existing assays to measure bacterial tactic responses, and it is flexible enough to be used in a wide range of different applications.Keywords
This publication has 34 references indexed in Scilit:
- CheZ Phosphatase Localizes to Chemoreceptor Patches via CheA-ShortJournal of Bacteriology, 2003
- Neutrophil chemotaxis in linear and complex gradients of interleukin-8 formed in a microfabricated deviceNature Biotechnology, 2002
- Mot protein assembly into the bacterial flagellum: a model based on mutational analysis of the motB geneJournal of Molecular Biology, 2000
- Microfluidic Diffusion-Based Separation and DetectionScience, 1999
- Open Channel Electrochromatography on a MicrochipAnalytical Chemistry, 1994
- Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a ChipScience, 1993
- Measurement of bacterial random motility and chemotaxis coefficients: I. Stopped‐flow diffusion chamber assayBiotechnology & Bioengineering, 1991
- Flagellar rotation and the mechanism of bacterial motilityNature, 1974
- The Range of Attractant Concentrations for Bacterial Chemotaxis and the Threshold and Size of Response over This RangeThe Journal of general physiology, 1973
- A Method for Measuring Chemotaxis and Use of the Method to Determine Optimum Conditions for Chemotaxis by Escherichia coliJournal of General Microbiology, 1973