Dose monitoring for boron neutron capture therapy using a reactor-based epithermal neutron beam
- 1 December 1996
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 41 (12) , 2789-2797
- https://doi.org/10.1088/0031-9155/41/12/015
Abstract
The aims of this study were (i) to determine the variation with time of the relevant beam parameters of a clinical reactor-based epithermal neutron beam for boron neutron capture therapy (BNCT) and (ii) to test a monitoring system for its applicability to monitor the dose delivered to the dose specification point in a patient treated with BNCT. For this purpose two fission chambers covered with Cd and two GM counters were positioned in the beam-shaping collimator assembly of the epithermal neutron beam. The monitor count rates were compared with in-phanton reference measurements of the thermal neutron fluence rate, the gamma-ray dose rate and the fast neutron dose rate, at a constant reactor power, over a period of 2 years. Differences in beam output, defined as the thermal neutron fluence rate at 2 cm depth in a phantom, of up to 15% were observed between various reactor cycles. A decrease in beam output of about 5% was observed in each reactor cycle. An unacceptable decrease of 50% in beam output due to malfunctioning of the beam filter assembly was detected. For safe and accurate treatment of patients, on-line monitoring of the beam is essential. Using the calibrated monitor system, the standard uncertainty in the total dose at depth due to variations with time of the beam output parameters has been reduced to a clinically acceptable value of 1% (one standard deviation).Keywords
This publication has 7 references indexed in Scilit:
- The neutron sensitivity of dosimeters applied to boron neutron capture therapyMedical Physics, 1996
- On-line beam monitoring for neutron capture therapy at the MIT Research ReactorNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1995
- Determination of dose components in phantoms irradiated with an epithermal neutron beam for boron neutron capture therapyMedical Physics, 1995
- Present status and perspectives of boron neutron capture therapyRadiotherapy and Oncology, 1994
- Boron neutron capture therapy (BNCT): A radiation oncology perspectiveInternational Journal of Radiation Oncology*Biology*Physics, 1994
- Boron neutron capture therapy for cancer. Realities and prospectsCancer, 1992
- What degree of accuracy is required and can be achieved in photon and neutron therapy?Radiotherapy and Oncology, 1987