Intra-observer and interobserver variability of biventricular function, volumes and mass in patients with congenital heart disease measured by CMR imaging
Open Access
- 16 September 2009
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 26 (1) , 57-64
- https://doi.org/10.1007/s10554-009-9501-y
Abstract
Cardiovascular magnetic resonance (CMR) imaging provides highly accurate measurements of biventricular volumes and mass and is frequently used in the follow-up of patients with acquired and congenital heart disease (CHD). Data on reproducibility are limited in patients with CHD, while measurements should be reproducible, since CMR imaging has a main contribution to decision making and timing of (re)interventions. The aim of this study was to assess intra-observer and interobserver variability of biventricular function, volumes and mass in a heterogeneous group of patients with CHD using CMR imaging. Thirty-five patients with CHD (7–62 years) were included in this study. A short axis set was acquired using a steady-state free precession pulse sequence. Intra-observer and interobserver variability was assessed for left ventricular (LV) and right ventricular (RV) volumes, function and mass by calculating the coefficient of variability. Intra-observer variability was between 2.9 and 6.8% and interobserver variability was between 3.9 and 10.2%. Overall, variations were smallest for biventricular end-diastolic volume and highest for biventricular end-systolic volume. Intra-observer and interobserver variability of biventricular parameters assessed by CMR imaging is good for a heterogeneous group of patients with CHD. CMR imaging is an accurate and reproducible method and should allow adequate assessment of changes in ventricular size and global ventricular function.Keywords
This publication has 25 references indexed in Scilit:
- Normal biventricular function, volumes, and mass in children aged 8 to 17 yearsJournal of Magnetic Resonance Imaging, 2009
- Reproducibility of MRI measurements of right ventricular size and function in patients with normal and dilated ventriclesJournal of Magnetic Resonance Imaging, 2008
- Evaluating the systemic right ventricle by CMR: the importance of consistent and reproducible delineation of the cavityJournal of Cardiovascular Magnetic Resonance, 2008
- Addition of the Long-Axis Information to Short-Axis Contours Reduces Interstudy Variability of Left-Ventricular Analysis in Cardiac Magnetic Resonance StudiesInvestigative Radiology, 2008
- Operator Induced Variability in Left Ventricular Measurements with Cardiovascular Magnetic Resonance is Improved After TrainingJournal of Cardiovascular Magnetic Resonance, 2007
- Improved reproducibility of right ventricular volumes and function estimation from cardiac magnetic resonance images using level‐set modelsMagnetic Resonance in Medicine, 2007
- Interstudy reproducibility of right ventricular volumes, function, and mass with cardiovascular magnetic resonanceAmerican Heart Journal, 2004
- Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady‐state free precession imaging sequencesJournal of Magnetic Resonance Imaging, 2003
- Quantification of right ventricular function with magnetic resonance imaging in children with normal hearts and with congenital heart diseaseAmerican Heart Journal, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986