Changes in the bone-cement interface after total hip replacement. An in vivo animal study.
- 1 October 1982
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 64 (8) , 1188-1200
- https://doi.org/10.2106/00004623-198264080-00009
Abstract
In order to study the temporal sequence of radiographic, histological, mechanical, bacteriological, and chemical changes around the femoral component following total hip replacement, a model was created by implanting plastic-on-metal total hip replacements in sheep and walking the animals on a concrete surface beginning six weeks postoperatively. This model demonstrated a decreased torsional rigidity between the prosthesis and the femoral cortex in all sheep. Failure of bonding occurred at the bone-cement interface and appears from our results to be most probably due to alterations in the functional stress of the proximal end of the femur following insertion of the femoral component rather than exothermic polymerization, toxicity of free monomer residue, or infection. Clinical Relevance: An understanding of the causes of loosening of cemented metal femoral components in total hip replacement has been thwarted by a lack of specimens at sequential times in the loosening process. Since a patient is not operated on until the prosthetic components are completely loose, such specimens are difficult to obtain clinically. For this reason a model for examining the bone-cement interface, measured by decreased torsional rigidity of the prosthesis relative to the bone, was developed in sheep. Of all the parameters studied, those inherent in the effects (mechanical or vascular, or both) of insertion of the prosthesis itself appeared to be the most likely cause of the change in the mechanical properties of the interface. This suggests that degenerative changes of the bone-cement interface may be inevitable.This publication has 7 references indexed in Scilit:
- The Classic: The Long-Term Results of Low-Friction Arthroplasty of the Hip Performed as a Primary Intervention*Clinical Orthopaedics and Related Research, 2005
- Monomer release from methacrylate bone cements during simulated in vivo polymerizationJournal of Biomedical Materials Research, 1979
- The relationship of functional stress and strain to the processes of bone remodelling. An experimental study on the sheep radiusJournal of Biomechanics, 1979
- Total hip arthroplasty.Journal of Bone and Joint Surgery, 1978
- Proximal strain distribution in the loaded femur. An in vitro comparison of the distributions in the intact femur and after insertion of different hip-replacement femoral components.Journal of Bone and Joint Surgery, 1978
- A longitudinal study of the radiolucent line at the bone-cement interface following total joint-replacement proceduresJournal of Bone and Joint Surgery, 1977
- Stress analysis of human femur with implanted Charnley prosthesisJournal of Biomechanics, 1977