A combined linear ion trap time‐of‐flight system with improved performance and MSn capabilities
- 4 September 2001
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 15 (19) , 1777-1795
- https://doi.org/10.1002/rcm.440
Abstract
A detailed description of a linear ion trap time‐of‐flight (TOF) mass spectrometer system, capable of sequential mass spectrometry (MSn), is given. Many improvements have been incorporated since the initial description of this system (Rapid Commun. Mass Spectrom. 1998; 12: 1463–1474). The pressure in the trap has been lowered from 7.0 to 1.8 mTorr, resulting in an increase in the mass resolution of ion excitation from 75 to 240. Use of the system for MS3 is demonstrated. Dipole excitation of the n = 1 harmonic, instead of the n = 0 fundamental frequency of ion motion, is shown to have a higher frequency resolution, f/Δf, but lower mass resolution, m/Δm. Both experiments and modeling demonstrate that at the lower pressure there is less collisional cooling of ions in the axial and radial directions of the trap. The efficiency of trapping is shown to be nearly 100% for periods up to 5 s. The demonstrated mass range for mass analysis has been extended to greater than m/z 16 250. To avoid the formation of adduct ions when trapping protein ions for extended times requires ultra‐high vacuum cleanliness conditions, even though the trap operates in the mTorr‐pressure range. Upgrading the TOF to a reflectron with higher quality ion optics results in an increase in the mass resolution of the TOF mass spectrometer to about 5000 at m/z 750. Copyright © 2001 John Wiley & Sons, Ltd.Keywords
This publication has 23 references indexed in Scilit:
- A new technique for unbiased external ion accumulation in a quadrupole two‐dimensional ion trap for electrospray ionization Fourier transform ion cyclotron resonance mass spectrometryRapid Communications in Mass Spectrometry, 2001
- A comparison of overtone and fundamental resonances for mass range extension by resonance ejection in a quadrupole ion trap mass spectrometerInternational Journal of Mass Spectrometry, 1999
- Collisional damping interface for an electrospray ionization time-of-flight mass spectrometerPublished by American Chemical Society (ACS) ,1998
- External accumulation of ions for enhanced electrospray ionization fourier transform ion cyclotron resonance mass spectrometryJournal of the American Society for Mass Spectrometry, 1997
- A collisional focusing ion guide for coupling an atmospheric pressure ion source to a mass spectrometerNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1997
- Alkali halide nanocrystalsAccounts of Chemical Research, 1993
- Ion isolation and sequential stages of mass spectrometry in a quadrupole ion trap mass spectrometerInternational Journal of Mass Spectrometry and Ion Processes, 1990
- Ion confinement in the collision cell of a multiquadrupole mass spectrometer: access to chemical equilibrium and determination of kinetic and thermodynamic parameters of an ion-molecule reactionAnalytical Chemistry, 1989
- Ion-trapping technique for ion/molecule reaction studies in the center quadrupole of a triple quadrupole mass spectrometerInternational Journal of Mass Spectrometry and Ion Processes, 1988
- Model calculations for alkali halide clustersThe Journal of Chemical Physics, 1985