Cardiovascular Monitoring During Elective Aortic Surgery
- 1 November 1983
- journal article
- research article
- Published by American Medical Association (AMA) in Archives of Surgery
- Vol. 118 (11) , 1256-1258
- https://doi.org/10.1001/archsurg.1983.01390110014003
Abstract
• We designed a prospective study to determine whether cardiac ejection fraction as measured noninvasively could isolate a subset undergoing aortic surgery for whom central venous pressure (CVP) predicted pulmonary artery wedge pressure (PAWP). Sixteen patients were studied. Simultaneous values of PAWP and CVP were analyzed, using linear regression analysis. A significant correlation between CVP and PAWP was found for the entire patient population and for each of four time periods: preoperative, before and after aortic cross-clamping, during aortic cross-clamping, and postoperative. A significant correlation between PAWP and CVP was found during the entire perioperative period for 14 of the 16 patients. However, the slope of the regression line, or the sensitivity of the CVP in reflecting changes in PAWP, was greater than 0.5 in only seven of the 16 patients. There was no correlation between the preoperative ejection fraction and the CVP/PAWP. We conclude that the CVP is an insensitive indicator of left ventricular filling pressure in most patients accepted for elective infrarenal aortic surgery, and monitoring of the PAWP is recommended. (Arch Surg 1983;118:1256-1258)This publication has 4 references indexed in Scilit:
- Maintenance of Cardiodynamics with Aspirin During Abdominal Aortic Aneurysmectomy (AAA)Annals of Surgery, 1981
- Monitoring Pulmonary Arterial Pressure in Coronary-artery DiseaseAnesthesiology, 1980
- Multifactorial Index of Cardiac Risk in Noncardiac Surgical ProceduresNew England Journal of Medicine, 1977
- Myocardial ischemia due to infrarenal aortic cross-clamping during aortic surgery in patients with severe coronary artery disease.Circulation, 1976