Antimony electrodes
- 1 August 1990
- journal article
- research article
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 35 (8) , 950-955
- https://doi.org/10.1007/bf01537242
Abstract
Antimony electrodes are clinically useful because of their low cost and simple construction; they have no glass to break. There is only a few hundred ohms resistance between an antimony pH electrode and the reference electrode so that the voltage generated can be recorded with simple low-impedance recorders linked to microcomputers. We used antimony pH electrodes with silver-silver chloride electrodes applied to the skin to measure the gastric pH in vivo and obtained erroneously high values. Using an ion-permeable dialysis chamber to surround electrodes in vivo, we showed that the discrepancy was caused by interference from gastric transmucosal potential difference. To circumvent the interference, we used a combination electrode constructed by embedding a monocrystalline antimony electrode and a silver-silver chloride reference electrode in dental acrylic. Antimony pH electrodes calibrated with commercial pH buffers also gave erroneous readings in HCl solutions of known pH. The erroneous readings were due, in part, to organic complex-forming ligands or organic salts such as potassium phthalate present in commercial buffer solutions. Accurate pH calibration can be obtained with citrate or acetate buffers or by using a normogram to correct for the errors introduced with commercial buffers. The combination antimony pH electrode has a number of potential clinical and research applications and simplifies obtaining accurate and reliable pH data in vivo.Keywords
This publication has 11 references indexed in Scilit:
- Statistics on microcomputers: a non-algebraic guide to their appropriate use in biomedical research and pathology laboratory practice. 4. Correlation and regression.Journal of Clinical Pathology, 1989
- Evaluation of antisecretory activity of misoprostol in duodenal ulcer patients using long-term intragastric pH monitoringDigestive Diseases and Sciences, 1988
- Identical 24-Hour Gastric pH Profiles When Using Intragastric Antimony or Glass Electrodes or Aspirated Gastric JuiceScandinavian Journal of Gastroenterology, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Mechanisms of Gastroesophageal Reflux in Patients with Reflux EsophagitisNew England Journal of Medicine, 1982
- Effects of some complex-forming ligands on the potential of antimony pH-sensorsTalanta, 1981
- Functional Significance of Gastric Mucosal Barrier to SodiumGastroenterology, 1964
- STUDIES ON THE ANTIMONY METAL ELECTRODE FOR pH DETERMINATIONThe Journal of Biochemistry, 1939
- THE ANTIMONY-ANTIMONY TRIOXIDE ELECTRODE AND ITS USE AS A MEASURE OF ACIDITY1Journal of the American Chemical Society, 1928