Iron and Manganese Removal with Ozonation in the Presence of Humic Substances
- 1 January 1989
- journal article
- research article
- Published by Taylor & Francis in Ozone: Science & Engineering
- Vol. 11 (1) , 93-113
- https://doi.org/10.1080/01919518908552514
Abstract
The conditions for the removal of iron and manganese contained in slightly mineralized water, rich in humic substances, were determined in a case where an intermediate oxidation was provided in a conventional potabilization line comprising a coagulationflocculation stage with iron salts. The experiments were conducted both on a synthetic water, with or without addition of humic substances, and on raw water from the Moulin-Papon dam. While iron was easily removed by simply increasing the pH measurement from 8.2 to 8.5 without intermediate oxidation, ozonation applied to water with a pH of nearly 8.4 did not enable the manganese to be removed with a low ozone dose (about 1 mg/L) unless a significant amount of bicarbonates (120 to 130 mg/L as CaCO3) were injected prior to the ozonation-filtration stage. As it removes the manganese from the water, intermediate ozonation also removes the abatement of organics on the filters, and lowers the THM buildup potential.Keywords
This publication has 4 references indexed in Scilit:
- The ozonation of organic halide precursors: effect of bicarbonateWater Research, 1986
- Decomposition of ozone in water in the presence of organic solutes acting as promoters and inhibitors of radical chain reactionsEnvironmental Science & Technology, 1985
- Preparative isolation of aquatic humic substancesEnvironmental Science & Technology, 1981
- Determination of ozone in water by the indigo methodWater Research, 1981