QUANTITATIVE ASSESSMENT OF BLOOD-FLOW IN PEDIATRIC RECIPIENTS OF RENAL-TRANSPLANTS
- 1 May 1990
- journal article
- research article
- Vol. 31 (5) , 580-585
Abstract
We applied a renal blood flow (RBF) quantification technique to pediatric data, which depends minimally on bolus shape, uses a conventional radiopharamaceutical 99mTc-DTPA, and generates a value for RBF as a percentage of cardiac output (RBF/CO). Mean RBF was 16.9% (.+-. 4.8) for normal transplants, 13.1% (.+-. 2.9) for transplnats undergoing mild-to-moderate chronic rejection, 7.9% (.+-. 1.3) for those with mild acute rejection and 3.3% (.+-. 1.4) for those with moderate-to-severe acute rejection. Very low blood flow values within 24 hr following transplantation may have prognostic significance. Patients who required transplant-nephrectomy had significantly lower RBF/CO values than children who retained their allograft.This publication has 0 references indexed in Scilit: