Degradation of biomaterials by phagocyte-derived oxidants.
Open Access
- 1 November 1993
- journal article
- Published by American Society for Clinical Investigation in Journal of Clinical Investigation
- Vol. 92 (5) , 2360-2367
- https://doi.org/10.1172/jci116841
Abstract
Polymers used in implantable devices, although relatively unreactive, may degrade in vivo through unknown mechanisms. For example, polyetherurethane elastomers used as cardiac pacemaker lead insulation have developed surface defects after implantation. This phenomenon, termed "environmental stress cracking," requires intimate contact between polymer and host phagocytic cells, suggesting that phagocyte-generated oxidants might be involved. Indeed, brief exposure of polyetherurethane to activated human neutrophils, hypochlorous acid, or peroxynitrite produces modifications of the polymer similar to those found in vivo. Damage to the polymer appears to arise predominantly from oxidation of the urethane-aliphatic ester and aliphatic ether groups. There are substantial increases in the solid phase surface oxygen content of samples treated with hypochlorous acid, peroxynitrite or activated human neutrophils, resembling those observed in explanted polyetherurethane. Furthermore, both explanted and hypochlorous acid-treated polyetherurethane show marked reductions in polymer molecular weight. Interestingly, hypochlorous acid and peroxynitrite appear to attack polyetherurethane at different sites. Hypochlorous acid or activated neutrophils cause decreases in the urethane-aliphatic ester stretch peak relative to the aliphatic ether stretch peak (as determined by infrared spectroscopy) whereas peroxynitrite causes selective loss of the aliphatic ether. In vivo degradation may involve both hypohalous and nitric oxide-based oxidants because, after long-term implantation, both stretch peaks are diminished. These results suggest that in vivo destruction of implanted polyetherurethane involves attack by phagocyte-derived oxidants.Keywords
This publication has 20 references indexed in Scilit:
- Peroxynitrite, a cloaked oxidant formed by nitric oxide and superoxideChemical Research in Toxicology, 1992
- Studies of poly(ether)urethane pacemaker lead insulation oxidationJournal of Biomedical Materials Research, 1987
- Oxidation of chloride and thiocyanate by isolated leukocytes.Journal of Biological Chemistry, 1986
- In vivo biocompatibility studies. V. In vivo leukocyte interactions with biomerJournal of Biomedical Materials Research, 1984
- A simple reliable assay for myeloperoxidase activity in mixed neutrophil-eosinophil cell suspensions: Application to detection of myeloperoxidase deficiencyJournal of Immunological Methods, 1984
- Polyether polyurethanes for implantable pacemaker leadsBiomaterials, 1982
- Surface and bulk characteristics of a polyether urethane for artificial heartsJournal of Biomedical Materials Research, 1975
- Tissue pathology and physical stability of a polyether elastomer on three‐year implantationJournal of Biomedical Materials Research, 1972
- Segmented polyurethane: A polyether polymer, II. Two years experienceJournal of Biomedical Materials Research, 1971
- Segmented Polyurethane: A New Elastomer for Biomedical ApplicationsScience, 1967