Abstract
We investigate the sensitivity of the conversions from entrance surface dose (ESD) or kerma-area product (KAP) to effective dose (E) or to energy imparted to the patient () to the likely variations in tube potential, field size, patient size and sex which occur in clinical work. As part of a factorial design study for chest and lumbar spine examinations, the tube potentials were varied to be ±10% of the typical values for the examinations while field sizes and the positions of the field centres were varied to be representative of values drawn from measurements on patient images. Variation over sex and patient size was based on anthropomorphic phantoms representing males and females of ages 15 years (small adult) and 21 years (reference adult). All the conversion coefficients were estimated using a mathematical phantom programmed with the Monte Carlo code EGS4 for all factor combinations and analysed statistically to derive factor effects. In general, the factors studied behaved independently in the sense that interaction of the physical factors generally gave no more than a 5% variation in a conversion coefficient. Taken together, variation of patient size, sex, field size and field position can lead to significant variation of E/KAP by up to a factor of 2, of E/ESD by up to a factor of 3, of /KAP by a factor of 1.3 and of /ESD by up to a factor of 2. While KAP is preferred to determine , the results show no strong preference of KAP over ESD in determining E. The mean absorbed dose in the patient obtained by dividing (determined using KAP) by the patient's mass was found to be the most robust measure of E.Keywords
This publication has 12 references indexed in Scilit:
- ICRP Publication 123: Assessment of Radiation Exposure of Astronauts in SpaceAnnals of the ICRP, 2013
- Effective dose and energy imparted in diagnostic radiologyMedical Physics, 1997
- An EGS4 Based Mathematical Phantom for Radiation Protection Calculations Using Standard ManHealth Physics, 1994
- Conversion Factors between Energy Imparted to the Patient and Air Collision Kerma Integrated over Beam Area in Pediatric RadiologyActa Radiologica, 1993
- Estimation of effective dose to the patient during medical X-ray examinations from measurements of the dose-area productPhysics in Medicine & Biology, 1992
- Radiation Doses to Sensitive Organs from Intraoral Dental RadiographyDento maxillo facial radiology, 1987
- Ein Programm für die Berechnung von diagnostischen RöntgenspektrenRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1985
- Energy imparted to the patient in diagnostic radiology: calculation of conversion factors for determining the energy imparted from measurements of the air collision kerma integrated over beam areaPhysics in Medicine & Biology, 1984
- A Somatic Dose Index for Diagnostic RadiologyHealth Physics, 1978