A study of effective attenuation coefficient for calculating tissue compensator thickness
- 1 January 1990
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 17 (1) , 117-121
- https://doi.org/10.1118/1.596561
Abstract
Dose uniformity throughout the treatment volume is essential to precision radiation therapy. Tissue compensators are often used as a means to eliminate dose nonuniformity resulting from surface contour irregularities. This paper evaluates the accuracy of using an effective attenuation coefficient for calculating the thickness of missing tissue. This coefficient is found to vary strongly with thickness of missing tissue when the initial depth is situated in the buildup region. The use of a single attenuation coefficient produces errors as high as 54% in the calculated compensator thickness when 10-MV x-rays are used. At depths greater than the depth of maximum dose, the attenuation coefficient remains a function of field size, not the initial depth.Keywords
This publication has 8 references indexed in Scilit:
- Computer aided design and verification of megavoltage tissue compensators for oblique beamsMedical Physics, 1988
- A practical approach to uniform total body photon irradiationInternational Journal of Radiation Oncology*Biology*Physics, 1986
- Compensating filters for high energy x raysMedical Physics, 1982
- A microcomputer‐based system for radiotherapy beam compensator design and patient contour plottingMedical Physics, 1982
- Improved method for the design of tissue compensatorsMedical Physics, 1981
- Thin lead sheets as tissue compensators for larger field irradiationInternational Journal of Radiation Oncology*Biology*Physics, 1980
- Basic data on tissue-equivalent compensators for 4-mv x-raysInternational Journal of Radiation Oncology*Biology*Physics, 1980
- The Use of Photogrammetry in Tissue Compensator DesignRadiology, 1977