Evaluation of Two Commercially Available, Inexpensive Alternative Assays Used for Assessing Viral Load in a Cohort of Human Immunodeficiency Virus Type 1 Subtype C-Infected Patients from South Africa
Open Access
- 1 February 2005
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 43 (2) , 857-861
- https://doi.org/10.1128/jcm.43.2.857-861.2005
Abstract
Although human immunodeficiency virus type 1 (HIV-1) RNA is the acknowledged “gold standard” marker for monitoring disease activity in patients receiving highly active antiretroviral therapy (HAART), it remains unaffordable in resource-constrained settings. The present study investigated two commercially available kits for the detection of HIV-1 viral load markers as more affordable alternatives to HIV-1 RNA quantitation. The greatly improved heat-denatured, signal-boosted HiSens HIV-1 p24 Ag Ultra kit (Perkin-Elmer) and the ExaVir Load Quantitative HIV-RT kit (Cavidi Tech AB) were compared with the Amplicor HIV-1 Monitor (version 1.5) assay (Roche Molecular Systems Inc.). A total of 117 samples containing HIV-1 subtype C were analyzed by all three methodologies. Eighty-nine of these samples represented serial measurements from 20 patients receiving HAART. The remaining samples analyzed were from a group of treatment-naïve patients. The association between the p24 antigen assay and the RNA assay was fairly strong ( R 2 = 0.686). The association between the reverse transcriptase (RT) quantitation assay and the RNA assay was strong ( R 2 = 0.810). Both alternative assays seemed most useful for the serial monitoring of patients receiving HAART ( n = 89 plasma samples from 20 patients), as all assays showed a statistically significant downward trend over time, with the trend being either linear or curvilinear. In addition, all three assays showed negative correlations with the CD4 count (CD4 count versus RNA load, r = −0.336 and P = 0.001; CD4 count versus p24 antigen level, r = −0.541 and P < 0.0001; CD4 count versus RT level, r = −0.358 and P = 0.0006). Still of major concern are both the lack of sensitivity and the wide degrees of variability of both assays. However, both assays provide a less expensive alternative to the Roche viral load assay and demonstrate the same trends during treatment.Keywords
This publication has 17 references indexed in Scilit:
- HIV‐1 viral load determination based on reverse transcriptase activity recovered from human plasmaJournal of Medical Virology, 2003
- A new quantitative HIV load assay based on plasma virion reverse transcriptase activity for the different types, groups and subtypesAIDS, 2003
- Short Communication: Relationship of CD4+ T Cell Counts and HIV Type 1 Viral Loads in Untreated, Infected AdolescentsAIDS Research and Human Retroviruses, 2000
- Human Immunodeficiency Virus Type 1 p24 Concentration Measured by Boosted ELISA of Heat‐Denatured Plasma Correlates with Decline in CD4 Cells, Progression to AIDS, and Survival: Comparison with Viral RNA MeasurementThe Journal of Infectious Diseases, 2000
- Prospective Evaluation of Amplification‐Boosted ELISA for Heat‐Denatured p24 Antigen for Diagnosis and Monitoring of Pediatric Human Immunodeficiency Virus Type 1 InfectionThe Journal of Infectious Diseases, 1999
- Measurement of Human Immunodeficiency Virus Type 1 Plasma Virus Load Based on Reverse Transcriptase (RT) Activity: Evidence of Variabilities in Levels of Virion‐Associated RTThe Journal of Infectious Diseases, 1998
- Direct Observation of Vortex Dynamics in Superconducting Films with Regular Arrays of DefectsScience, 1996
- Prognosis in HIV-1 Infection Predicted by the Quantity of Virus in PlasmaScience, 1996
- Sensitive Detection and Early Prognostic Significance of p24 Antigen in Heat-Denatured Plasma of Human Immunodeficiency Virus Type 1-Infected InfantsThe Journal of Infectious Diseases, 1994
- Quantitative and sensitive detection of immune-complexed and free HIV antigen after boiling of serumJournal of Virological Methods, 1993